Related Experiment Video
Updated: Apr 11, 2026

Calculating Heart Rate Variability from ECG Data from Youth with Cerebral Palsy During Active Video Game Sessions
Published on: June 5, 2019
Cross-Validation of a PACER Prediction Equation for Assessing Aerobic Capacity in Hungarian Youth
Pedro F Saint-Maurice1, Gregory J Welk, Kevin J Finn
1a Iowa State University.
Purpose:
The purpose of this article was to evaluate the validity of the Progressive Aerobic Cardiovascular and Endurance Run (PACER) test in a sample of Hungarian youth.
Method:
Approximately 500 participants (aged 10-18 years old) were randomly selected across Hungary to complete both laboratory (maximal treadmill protocol) and field assessments (PACER) of aerobic capacity. Agreement between lab- and PACER-derived peak oxygen consumption (VO2) was examined using linear regression and 2-sided equivalence testing techniques, respectively. The impact of agreement on the classification accuracy of peak VO2 estimates into FITNESSGRAM® fitness zones was determined with kappa statistics.
Results:
The final sample resulted in a total of 167 boys and 143 girls (N = 310). Analyses revealed that lab and PACER VO2 shared 13% to 18% of their variance (R(2)boys = .13, R(2)girls = .18) and that limits of agreement ranged from - 39.9 mL/kg/min to +37.6 mL/kg/min depending on the sex. The absolute error values were 14% for boys and 16% for girls; however, the average peak VO2 estimates from the PACER were within the 10% equivalence region for girls (37.2 mL/kg/min to 45.4 mL/kg/min), but not for boys (45.2 mL/kg/min to 55.2 mL/kg/min). When lab and PACER VO2 were categorized according to Fitnessgram zones, agreement was fair for both sexes (boys, Kappa = .25, and girls, Kappa = .31).
Conclusions:
Although the correlations between measured and predicted peak VO2 were lower than expected, the magnitude of error observed in the PACER is similar to past ranges of error observed in other studies (10%-15%), but the large individual error should be considered when interpreting individual results from this field-based measure of aerobic capacity. There was reasonable classification agreement between lab estimates and the PACER test for classification into the various fitness standards.
Related Concept Videos
Assessment of blood pressure in brachial artery(two-step method)
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
Pulmonary Function Tests
Pulmonary Function Tests are crucial diagnostic tools for assessing respiratory function, particularly in patients with chronic respiratory disorders. They comprehensively evaluate lung volumes, ventilatory function, breathing mechanics, diffusion, and gas exchange. These tests help diagnose pulmonary diseases and play a significant role in monitoring disease progression, evaluating disability, and assessing response to therapy.
PFTs involve using a spirometer, a...

