Related Experiment Video
Updated: Apr 11, 2026

In Vivo Luminal Measurement of Distension-Evoked Urothelial ATP Release in Rodents
Published on: September 7, 2022
Response Properties of Urethral Distension Evoked Unifiber Afferent Potentials in the Lower Urinary Tract
Monica Eggermont1, Jean-Jacques Wyndaele1, James Gillespie1
1Department of Urology, Antwerp University Hospital and Faculty of Medicine, University of Antwerp, Antwerp, Belgium; Uro-Physiology Research Group, Dental and Medical School, Newcastle University (JG), Newcastle upon Tyne, United Kingdom.
Purpose:
It is well known that afferent input from the urethra can modulate bladder function. Nevertheless, little is known about the functional properties of urethral afferents. In the current study we investigated the effect of urethral distension on single fiber afferent activities of the lower urinary tract in the female rat.
Materials And Methods:
Female Sprague Dawley® rats were anesthetized. Single fiber afferent activities were recorded from the left L6 dorsal root and classified by conduction velocity. The response of pelvic and pudendal units on urethral distension (60 seconds) was measured. Two distension diameters were measured in the proximal and the distal urethra.
Results:
A total of 93 pelvic and 72 pudendal units were isolated in 15 rats. Of the units 20 (8 pelvic and 12 pudendal) were responsive to urethral distension. Three patterns of response could be distinguished, including a fast adapting and 2 groups of slow adapting afferents. The largest grade of distension resulted in the greatest response in both nerves. Five pelvic and 3 pudendal units responded exclusively to proximal distension, 2 pelvic and 5 pudendal units responded to distal distension, and 1 pelvic and 4 pudendal units responded to both types of distension. The responses were reproducible. No association was found between the type of nerve and the location of the response to distension.
Conclusions:
This electrophysiological study demonstrates the presence of urethral distension evoked afferents in the pelvic and pudendal nerves, and describes their response to distension. Differences in sensory signaling in type and in location were demonstrated. The current technique can be used for further investigation of urethral afferents.
More Related Videos
11:46Urinary Bladder Distention Evoked Visceromotor Responses as a Model for Bladder Pain in Mice
Published on: April 27, 2014
06:36A Decentralized Ex Vivo Murine Bladder Model with the Detrusor Muscle Removed for Direct Access to the Suburothelium during Bladder Filling
Published on: November 28, 2019
Related Concept Videos
Anatomy of the Genitourinary System II: Bladder and Urethra
Urethra
The anatomy of the urethra differs between males and females. In females, the urethra is short, measuring about 3–4 cm in length, and opens anterior to the vaginal opening. In males, the urethra is longer and passes through the penis, serving dual purposes: expelling urine and ejaculating semen. The male...
The Micturition Reflex
The process begins with bladder filling, where the bladder wall stretches as urine accumulates. This stretching activates the urine storage reflex, mediated by the sacral spinal segments and the pontine storage center. Efferent sympathetic impulses stimulate the detrusor muscle to relax and the internal urethral sphincter to contract, facilitating...
Microbiota of the Urogenital Tract
Urodynamic Studies: Uroflowmetry
Urinary Bladder
In males, the bladder is situated in front of the rectum, while in females, it is positioned anterior to the vagina and uterus. The bladder floor contains an inverted triangular area called the trigone, defined by the two ureteric...