Related Experiment Video
Updated: Apr 11, 2026

Upper-extremity Approach for Secondary Access in Transfemoral Transcatheter Aortic Valve Implantation
Published on: August 8, 2025
2-Year Outcomes in Patients Undergoing Surgical or Self-Expanding Transcatheter Aortic Valve Replacement
Michael J Reardon1, David H Adams2, Neal S Kleiman1
1Houston Methodist DeBakey Heart & Vascular Center, Houston, Texas.
Background:
The U.S. pivotal trial for the self-expanding valve found that among patients with severe aortic stenosis at increased risk for surgery, the 1-year survival rate was 4.9 percentage points higher in patients treated with a self-expanding transcatheter aortic valve bioprosthesis than in those treated with a surgical bioprosthesis.
Objectives:
Longer-term clinical outcomes were examined to confirm if this mortality benefit is sustained.
Methods:
Patients with severe aortic stenosis who were at increased surgical risk were recruited. Eligible patients were randomly assigned in a 1:1 ratio to transcatheter aortic valve replacement with the self-expanding transcatheter valve (transcatheter aortic valve replacement [TAVR] group) or to aortic valve replacement with a surgical bioprosthesis (surgical group). The 2-year clinical and echocardiographic outcomes were evaluated in these patients.
Results:
A total of 797 patients underwent randomization at 45 centers in the United States. The rate of 2-year all-cause mortality was significantly lower in the TAVR group (22.2%) than in the surgical group (28.6%; log-rank test p < 0.05) in the as-treated cohort, with an absolute reduction in risk of 6.5 percentage points. Similar results were found in the intention-to-treat cohort (log-rank test p < 0.05). The rate of 2-year death or major stroke was significantly lower in the TAVR group (24.2%) than in the surgical group (32.5%; log-rank test p = 0.01).
Conclusions:
In patients with severe aortic stenosis who are at increased surgical risk, the higher rate of survival with a self-expanding TAVR compared with surgery was sustained at 2 years. (Safety and Efficacy Study of the Medtronic CoreValve System in the Treatment of Symptomatic Severe Aortic Stenosis in High Risk and Very High Risk Subjects Who Need Aortic Valve Replacement; NCT01240902).