Related Experiment Video
Updated: Apr 11, 2026

3D Orbital Tracking in a Modified Two-photon Microscope: An Application to the Tracking of Intracellular Vesicles
Published on: October 1, 2014
Marker-Free Tracking of Facet Capsule Motion Using Polarization-Sensitive Optical Coherence Tomography
Amy A Claeson1, Yi-Jou Yeh2, Adam J Black3
1Department of Biomedical Engineering, University of Minnesota, Minneapolis, MN, 55455, USA. claes027@umn.edu.
Abstract:
We proposed and tested a method by which surface strains of biological tissues can be captured without the use of fiducial markers by instead, utilizing the inherent structure of the tissue. We used polarization-sensitive optical coherence tomography (PS OCT) to obtain volumetric data through the thickness and across a partial surface of the lumbar facet capsular ligament during three cases of static bending. Reflectivity and phase retardance were calculated from two polarization channels, and a power spectrum analysis was performed on each a-line to extract the dominant banding frequency (a measure of degree of fiber alignment) through the maximum value of the power spectrum (maximum power). Maximum powers of all a-lines for each case were used to create 2D visualizations, which were subsequently tracked via digital image correlation. In-plane strains were calculated from measured 2D deformations and converted to 3D surface strains by including out-of-plane motion obtained from the PS OCT image. In-plane strains correlated with 3D strains (R(2) ≥ 0.95). Using PS OCT for marker-free motion tracking of biological tissues is a promising new technique because it relies on the structural characteristics of the tissue to monitor displacement instead of external fiducial markers.
More Related Videos
08:50Longitudinal Morphological and Physiological Monitoring of Three-dimensional Tumor Spheroids Using Optical Coherence Tomography
Published on: February 9, 2019
12:54Simultaneous Brightfield, Fluorescence, and Optical Coherence Tomographic Imaging of Contracting Cardiac Trabeculae Ex Vivo
Published on: October 2, 2021
Related Concept Videos
Confocal Fluorescence Microscopy
Total Internal Reflection Fluorescence Microscopy
Atomic Force Microscopy
The AFM Probe
The probe is regarded as the heart of any AFM setup and comprises the...
Curvilinear Motion: Polar Coordinates
The particle's location is described using a unit vector along the radial direction. Deriving the particle's position...
Mechanism of Ciliary Motion
The cilia are made up of microtubules in a 9+2 arrangement, with nine microtubule doublet ring bundles, surrounding a pair of central singlet microtubule bundles. The doublet microtubule bundles are...
Mechanism of Ciliary Motion