Related Experiment Video
Updated: Apr 11, 2026

Automated 90Sr Separation and Preconcentration in a Lab-on-Valve System at Ppq Level
Published on: June 6, 2018
Development of a rotary disc voltammetric sensor system for semi-continuous and on-site measurements of Pb(II)
Yong-Gu Lee1, Jungyoup Han2, Soondong Kwon3
1Department of Water Resource, Graduate School of Water Resources, Sungkyunkwan University, 2066 Seobu-ro, Jangan-Gu, Suwon, Gyeonggi-Do 440-746, Republic of Korea.
Abstract:
Atomic absorption spectrometry and inductively coupled plasma-mass spectrometry are widely used for determination of heavy metals due to their low detection limits. However, they are not applicable to on-site measurements of heavy metals as bulky equipment, and highly skilled laboratory staffs are needed as well. In this study, a novel analytical method using a rotary disc voltammetric (RDV) sensor has been successfully designed, fabricated and characterized for semi-continuous and on-site measurements of trace levels of Pb(II) in non-deoxygenating solutions. The square wave anodic stripping voltammetry was used to improve the sensitivity of the Pb(II) detection level with less than 10nM (2μgL(-1)). The RDV sensor has 24-sensing holes to measure concentrations of Pb(II) semi-continuously at sampling sites. Each sensing hole consists of a silver working electrode, an integrated silver counter, and a quasi-reference electrode, which requires only a small amount of samples (<30μL) for measurement of Pb(II) without disturbing and/or clogging the sensing environment. In addition, the RDV sensor showed a correlation coefficient of 0.998 for the Pb(II) concentration range of 10nM-10μM at the deposition time of 180s and its low detection limit was 6.19nM (1.3μgL(-1)). These results indicated that the advanced monitoring technique using a RDV sensor might provide environmental engineers with a reliable way for semi-continuous and on-site measurements of Pb(II).
More Related Videos
08:03Multi-analyte Biochip MAB Based on All-solid-state Ion-selective Electrodes ASSISE for Physiological Research
Published on: April 18, 2013
13:09Assessment of Boron Doped Diamond Electrode Quality and Application to In Situ Modification of Local pH by Water Electrolysis
Published on: January 6, 2016
Related Concept Videos
Voltammetry: Stripping Methods
Anodic Stripping Voltammetry (ASV)
ASV is used to determine metals and metalloids at trace levels. It involves two steps: deposition and stripping. First, a negative potential is applied to the...
Voltammetry: Overview
A voltammetric cell uses three electrodes: a working electrode, a reference electrode, and an auxiliary electrode. The redox reactions occur in the working...
Voltammetric Techniques: Linear-Scan (E vs Time)
Potentiometry: Membrane Electrodes
Voltammetric Techniques: Pulse Voltammetry