Related Experiment Video
Updated: Apr 11, 2026

Introduction of Intracapsular Rotary-cut Procedures IRCP: A Modified Hysteromyomectomy Procedures Facilitating Fertility Preservation
Published on: January 17, 2019
Robotic hysterectomy or myomectomy without power morcellation: A single-port assisted three-incision technique with
Gun Oh Chong1, Yoon Hee Lee1, Dae Gy Hong1
1Department of Obstetrics and Gynaecology, School of Medicine, Kyungpook National University Medical Centre, Daegu, South Korea.
Background:
The purpose of this study was to evaluate the feasibility and safety of a single-port assisted three-incision robotic hysterectomy or myomectomy with manual morcellation using a scalpel, and to introduce our novel surgical technique.
Methods:
Between October 2010 and July 2014, 16 patients underwent robotic hysterectomy and 50 patients underwent robotic myomectomy using a single-port assisted three-incision technique. Manual morcellation through a single-port site without power morcellation was used to remove the uterus or uterine fibroids.
Results:
The mean operative times were 130.2 ± 32.6 min in the hysterectomy group and 178.8 ± 77.9 min in the myomectomy group. Intraoperative complications, including a rectal serosa injury and a small bowel injury, occurred in two cases. Three febrile morbidities occurred postoperatively. Finally, no complications were associated with manual morcellation.
Conclusions:
Uterine tissues could be removed without any complications by manual morcellation within an endobag, using a scalpel. Copyright © 2015 John Wiley & Sons, Ltd.