Related Experiment Video
Updated: Apr 11, 2026

Author Spotlight: Enhancing Vascular Function and Physical Capacity in Cardiovascular Disease Through Novel Interventions and NIRS Technology
Published on: March 22, 2024
Getting the most from venous occlusion plethysmography: proposed methods for the analysis of data with a
Stephen Wythe1, Thomas Davies2, Daniel Martin2
1University College London Centre for Altitude Space and Extreme Environment Medicine, UCLH NIHR Biomedical Research Centre, Institute of Sport and Exercise Health, 170 Tottenham Court Road, London, W1T 7HA UK ; TamesAide General Hospital, Fountain Street, Ashton-U-Lyne OL6 9RW, Greater Manchester, UK.
Background:
Venous occlusion plethysmography is a simple yet powerful technique for the non-invasive measurement of blood flow. It has been used extensively in both the experimental and clinical settings. The underlying rationale is that when venous outflow from an extremity is occluded, any immediate increase in volume of this compartment must originate from the on-going arterial inflow. Mercury-in-silastic strain gauges are typically used to measure these volume changes, the rates of which are directly proportional to blood flow.
Results:
When using a simple rest/exercise protocol to provide a local or systemic metabolic stimulus to increase blood flow, current methods for analysing the data obtained are often rather simplistic, solely considering the mean increment in blood flow induced by exercise. Previous methodological considerations have focused mainly on issues of reproducibility and accuracy (for instance, by comparing unilateral and/or bilateral measurements) but rarely on what the recorded traces may actually mean.
Conclusions:
In this methodological manuscript, we suggest a more detailed approach to processing venous occlusion plethysmography data, one which could provide additional physiological information. Six parameters are described, all of which are easily derived from a simple and reproducible experimental rest/exercise venous occlusion plethysmography protocol.
Related Concept Videos
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
Venous Return
What is Venous Return?
Venous return refers to the rate at which blood flows back to the heart from the body's peripheral veins. It's an integral part of the circulatory system...
Venous Thrombosis II: Clinical Manifestations and Diagnostic Studies