Related Experiment Video
Updated: Apr 11, 2026

A Simple Method for Automated Solid Phase Extraction of Water Samples for Immunological Analysis of Small Pollutants
Published on: January 1, 2016
Sensitive detection of atrazine in tap water using TELISA
Zhiwei Qie1, Jialei Bai, Bin Xie
1Tianjin Key Laboratory of Risk Assessment and Control Technology for Environment and Food Safety, Tianjin Institute of Health and Environmental Medicine, Tianjin 300050, PR China. ningba@163.com gaozhx@163.com.
Abstract:
A highly sensitive flow injection analysis (FIA)-based thermal enzyme-linked immunoassay, TELISA, was developed for the rapid detection of atrazine (ATZ) in tap water. ATZ and β-lactamase-labeled ATZ were employed in a competitive immunoassay using a monoclonal antibody (mAb). After the off-column liquid-phase competition, the mAb was captured on the Protein G Sepharose™ 4 Fast Flow (PGSFF) column support material. Injected β-lactamase substrate ampicillin was degraded by the column-bound ATZ-β-lactamase, generating a detectable heat signal. Several assay parameters were optimized, including substrate concentration, flow rates and regeneration conditions, as well as the mAb and ATZ-β dilution ratios and concentrations. The assay linear range was 0.73-4.83 ng mL(-1) with a detection limit of 0.66 ng mL(-1). An entire heat signal requires 10 min for generation, and the cycle time is less than 40 min. The results were reproducible and stable. ATZ-spiked tap water samples exhibited a recovery rate of 103%-116%, which correlated with the UHPLC-MS/MS measurements. We attributed this significant increase in sensitivity over our previously published work to the following factors: (i) the capture of already-formed immune complexes on the column via immobilized Protein G, which eliminated chemical immobilization of the antibody; (ii) off-column preincubation allows the formation of immune complexes under nearly ideal conditions; and (iii) multiple buffers can be used to, in one case, enhance immune-complex formation and in the other to maximize enzymatic activity. Furthermore, the scheme creates a universal assay platform in which sensing is performed in the off-column incubation and detection after capture in the enzyme thermistor (ET) detector, which opens up the possibility of detecting any antigen for which antibodies were available.
More Related Videos
11:19Preparation and Testing of Impedance-based Fluidic Biochips with RTgill-W1 Cells for Rapid Evaluation of Drinking Water Samples for Toxicity
Published on: March 7, 2016
08:13A Filter-based Surface Enhanced Raman Spectroscopic Assay for Rapid Detection of Chemical Contaminants
Published on: February 19, 2016