Successful implantation of a second-generation aortic valve in severe aortic regurgitation secondary to a traumatic cusp lesion
Related Experiment Video
Updated: Apr 10, 2026

Standardized Technique of Aortic Valve Re-implantation for Valve-sparing Aortic Root Replacement
Published on: December 11, 2017
Antonio Mangieri1, Azeem Latib2, Andrea Aurelio1
1Cardio-Thoracic-Vascular Department, San Raffaele Institute, Milan, Italy.
Abstract:
A 67-year-old man with a dilated cardiomyopathy and severe aortic regurgitation (AR) secondary to a traumatic cusp lesion was referred to our institution because of progressive worsening of dyspnea. After formal discussion in the heart team, the patient was scheduled for TAVI (transcatheter aortic valve implantation). The pre procedural computed tomography scan revealed a minimum amount of calcium on the aortic valve and low position of coronary ostia. The TAVI procedure was performed with the implantation of a fully retrievable and repositionable aortic valve prosthesis (Direct Flow 29 mm, Direct Flow Medical, Santa Rosa, California) with an excellent result and no paravalvular leak. The TAVI devices designed for the treatment of calcific aortic stenosis have numerous limitations for the treatment of pure AR such as the risk of residual AR, the lack of repositionability and retrievability, and the need for valve- in-valve implantation. We believe that treatment of selected cases of pure AR with the Direct Flow valve is feasible and takes advantage of the retrievability of the prosthesis.
Related Concept Videos
Aortic Regurgitation III: Medical Management
Aortic Regurgitation II: Clinical Features and Diagnostic Tests
Aortic Regurgitation I: Introduction
Aortic Regurgitation IV: Nursing Management
Aneurysm III: Interprofessional Care