Related Experiment Video
Updated: Apr 10, 2026

Enumeration of Major Peripheral Blood Leukocyte Populations for Multicenter Clinical Trials Using a Whole Blood Phenotyping Assay
Published on: September 16, 2012
Temperature-Sensitive Indicators for Monitoring RBC Concentrates Out of Controlled Temperature Storage
Joerg P Sigle1, Andreas Holbro2, Thomas Lehmann3
1From the Blood Transfusion Center beider Basel, Swiss Red Cross, Basel, Switzerland; Blood Transfusion Center Aargau-Solothurn, Swiss Red Cross, Aarau, Switzerland; and joerg.sigle@blutspende-aarau.ch.
Objectives:
The 30-minute rule for RBC concentrates out of controlled temperature storage does not take into account multiple parameters that influence warming of RBC concentrates. This study evaluated two temperature-sensitive indicators (TIs) for monitoring RBC concentrates during transport.
Methods:
TI labels (Check-Spot [Harald H. Temmel KG, Gleisdorf, Austria] and Thermoindikator V4 [BASF, Basel, Switzerland]) were attached to RBC concentrates prior to delivery. Duration of transport, ambient temperatures, and label results (valid vs expired) were recorded. We evaluated the proportion of labels discrepant to the 30-minute rule overall and among deliveries 30 minutes or less and more than 30 minutes and compared the rates of valid and expired readings between both TIs.
Results:
In total, 201 RBC concentrate deliveries (86.6%) lasted 30 minutes or less, and 31 (13.4%) were more than 30 minutes. Forty-six (19.8%) Check-Spot and 37 (15.9%) Thermoindikator V4 results were discrepant to the 30-minute rule. Sixteen (51.6%) and 27 (87.1%) RBC concentrate deliveries more than 30 minutes displayed valid label readings with Check-Spot and Thermoindikator V4, respectively. Rates of expired labels among deliveries 30 minutes or less and valid labels among deliveries more than 30 minutes differed significantly between TIs (P < .01).
Conclusions:
TIs identified a considerable number of RBC concentrates whose temperatures may not be adequately reflected by the 30-minute rule. Variability of readings between TIs stresses the necessity of validation prior to implementation.
Related Concept Videos
Sample Handling
Samples should be transported carefully from collection points to the laboratory. They should be properly sealed and clearly labeled to prevent cross-contamination. To preserve the sample integrity, optimal temperature conditions during transport are essential. This could involve using...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...