Shear-wave elastography in invasive ductal carcinoma: correlation between quantitative maximum elasticity value and
Eun Yoon Cho1, Eun Sook Ko2, Boo-Kyung Han3
1Department of Pathology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea.
Background:
Further information is needed regarding whether histopathological characteristics affect breast tumor elasticity.
Purpose:
To determine whether maximum elasticity values vary according to tumor-stroma ratio, dominant stroma type, or presence of fibrosis in invasive breast cancer.
Material And Methods:
This study included 71 patients with invasive ductal carcinoma not otherwise specified (IDC NOS) who underwent breast shear-wave elastography (SWE). Maximum elasticity (Emax) values were retrospectively correlated with pathological findings that included tumor-stroma ratio, dominant stroma type (collagen, fibroblast, lymphocyte), and fibrosis. Multiple linear regression analysis was performed to determine variables independently associated with Emax.
Results:
High histologic grade was significantly correlated with higher Emax (P = 0.042). Estrogen receptor and progesterone receptor expression negatively correlated with high elasticity values (P = 0.013 and P = 0.03, respectively). Breast cancers that exhibited higher cellularity demonstrated a greater level of stiffness that was not statistically significant (ρ = 0.153; P = 0.193). While dominant stroma type and fibrosis did not affect Emax (P = 0.197 and P = 0.598, respectively), lesion size was significantly associated with Emax (ρ = 0.474, P < 0.001). On multivariate analysis, only lesion size was significantly associated with Emax (P < 0.001).
Conclusion:
The composition of tumors did not affect their Emax.
Related Concept Videos
Dynamic Modulus of Elasticity of Concrete
The sonic test is a common method to determine the dynamic modulus. In this test, a concrete beam, sized either 6 x 6 x 30 inches or 4 x 4 x 20 inches, is clamped at its center. Vibrations are initiated at one end of the beam by an electromagnetic exciter unit powered by a...
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):
Yield Criteria for Ductile Materials under Plane Stress
The Maximum Shearing Stress Criterion, also known as...