Casey Lo1,2, Deirdre Murphy3, Robyn Summerhayes1
1Department of Cardiothoracic Surgery, The Alfred Hospital, Prahran, Vic., Australia.
Abstract:
Postoperative right ventricular failure is a serious complication for up to 50% of patients following LVAD insertion. Predicting RV failure is an important factor for patients as planned BiVAD support has been shown to correlate with better outcomes compared to delayed BiVAD to LVAD conversion. This retrospective study examined prospectively collected data for 101 patients implanted with an LVAD between 2003 and 2013, aiming to establish preoperative predictive factors for RVF post-LVAD insertion, analyze outcomes, and validate existing RVF scoring systems. In our cohort, 63 patients (62.4%) developed RV failure and consequently demonstrated consistently poorer survival throughout the follow-up period (log-rank p = 0.01). Multivariable logistic regression identified two significant variables: cardiac index <2.2 preoperatively despite inotropic support (OR 4.6 [95%CI 1.8-11.8]; p = 0.001) and preoperative tricuspid regurgitation (OR 8.1 [95%CI 1.9-34]; p = 0.004). Patients who developed RV failure had more complicated postoperative courses including longer ICU stay (p < 0.001), higher incidence of transfusions (p = 0.03) and re-intubation (p = 0.001), longer ventilation duration (p < 0.001), and higher incidence of returning to theater (p = 0.0008). This study found that previous validation models had only moderate correlation with our population emphasizing the need for prospective validation of these scores in the current era of continuous flow devices.
More Related Videos
05:18Implantation of Left Ventricular Assist Device (LVAD) in Juvenile Landrace Swine: A LVAD Implantation Model of Pediatric Heart Failure
Published on: January 16, 2026
07:41Insertion, Maintenance, and Removal of the Percutaneous Dual Lumen Cannula Right Ventricular Assist Device
Published on: July 20, 2022
Related Concept Videos
Cardiomyopathy V: Interprofessional Care
Cardiomyopathy II: Dilated Cardiomyopathy
Mitral Stenosis I: Introduction
Mitral Regurgitation I: Introduction
Heart Failure VI: Adjunct Therapies
Imbalances in Cardiac Output
CHF can occur due to the failure of either side of the heart. Left-side failure leads to pulmonary congestion—the right side continues to send...