Measuring the Behavioral Effects of Intraocular Scatter
Published on: February 18, 2021
Influence of light filters in intraocular lenses on color perception and contrast acuity
Elfriede Wissiak1, Navid Ardjomand1, Gernot Steinwender1
1From the Department of Ophthalmology (Wissiak, Ardjomand, Steinwender, Wirtitsch), Medical University Graz, Graz, the Department of Ophthalmology (Prskavec), Hietzing Hospital and the Center for Medical Statistics (Kohl), Informatics and Intelligent Systems, Medical University of Vienna, Vienna, and the Department of Ophthalmology (Baradaran-Dilmaghani), St. Josef Hospital, Braunau, Austria.
Purpose:
To compare contrast acuity at different illumination levels, color vision, and the subjective visual impression in patients after bilateral cataract surgery with mixed implantation of a yellow-tinted intraocular lens (IOL) and an orange-tinted IOL.
Setting:
Department of Ophthalmology, Hietzing Hospital, Vienna, Austria.
Design:
Prospective case series.
Methods:
Consecutive patients with age-related cataract had standardized small-incision cataract surgery with IOL implantation in the capsular bag. Patients were randomly assigned to receive a yellow Polylens Y30 in 1 eye and an Orange Series model PC 440Y in the contralateral eye. The main outcome measures were contrast acuity, color vision, and subjective visual impression. Contrast acuity was measured at illumination levels of 5.0 lux and 0.5 lux and contrast levels of 50.0%, 25.0%, and 12.5%. Color vision was assessed using the Heidelberg-multicolor anomaloscope, and the subjective visual impression was evaluated using a questionnaire.
Results:
This study included 64 eyes of 32 patients. The intraindividual comparison showed no significant difference in contrast sensitivity at different contrast and illumination levels or in color vision. On questioning, 3 patients reported a difference in subjective color perception between the 2 IOL types.
Conclusion:
There were no differences in contrast sensitivity or color vision between yellow-tinted IOLs and orange-tinted IOLs.
Financial Disclosure:
No author has a financial or proprietary interest in any material or method mentioned.
More Related Videos
06:55Scanning Light Scattering Profiler SLPS Based Methodology to Quantitatively Evaluate Forward and Backward Light Scattering from Intraocular Lenses
Published on: June 6, 2017
04:59Author Spotlight: Enhancing Visual Outcomes in Cataract Surgery: A Novel Technique to Prevent Posterior Capsular Opacification Through IOL Rotation
Published on: July 7, 2023
Related Concept Videos
Photoreceptors and Visual Pathways
Focusing of Light in the Eye
Imaging Biological Samples with Optical Microscopy
In optical microscopy, the specimen to be viewed is placed on a glass slide and clipped on the stage...
Anatomy of the Eyeball
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Vision