The effect of chart speed on fetal monitor interpretation
David Peleg1, Reut Ram1, Steven L Warsof2
1a Department of Obstetrics and Gynecology, Faculty of Medicine , Ziv Medical Center Affiliated with the Bar-Ilan University , Galilee , Israel .
Objective:
Electronic fetal heart monitor chart speeds vary between countries, and it is unclear whether differing chart speeds affect physician tracing interpretation.
Methods:
Twenty-minute segments of 19 tracings were displayed on both 1 and 3 cm/min strips and interpreted by 14 physicians at the particular speed they were accustomed to reading. Interpretations of tracing characteristics were compared between groups using free margin kappa, a measure of interobserver agreement.
Results:
Compared to 3 cm/min tracings, 1 cm/min tracings were significantly more often identified as having absent than minimal variability, and minimal than moderate variability. Accelerations were significantly more often identified in 1 versus 3 cm/min strips. There were no significant differences between groups with respect to baseline fetal heart rate, prolonged or repetitive decelerations, or American College of Obstetricians and Gynecologists tracing category. Neither chart speed had substantial interobserver agreement in tracing variables; however, agreement was consistently higher in 3 versus 1 cm/min tracings (all p < 0.05).
Conclusions:
Tracing interpretation is significantly affected by fetal monitor chart speed with regards to variability, acceleration and deceleration. Further studies are required to determine if differences in chart speed interpretation affect clinical management.
Related Concept Videos
Fetal Circulation
Two umbilical arteries transport blood from the fetus to the placenta. At the placenta, the blood absorbs oxygen and nutrients while simultaneously eliminating waste products. This oxygen-enriched and nutrient-rich blood then returns to the fetus through one...
Cardiac Output I:Effect of Heart Rate on Cardiac Output
Cardiac output (CO) refers to the total amount of blood ejected by one of the ventricles in liters per minute (L/min). In a resting adult, CO ranges from 5 to 6 L/min, adjusting according to the body's metabolic requirements.
Effect of Heart Rate on Cardiac Output
Cardiac output adapts to metabolic demands during stress, physical activity, or illness. The autonomic nervous system regulates heart rate via the sinoatrial node. The parasympathetic nervous system decreases heart...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Dysrhythmias III: Characteristics of Dysrhythmias
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation: