Impact of high (131)I-activities on quantitative (124)I-PET
P E N Braad1, S B Hansen, P F Høilund-Carlsen
1Department of Nuclear Medicine Odense University Hospital Sdr. Boulevard 29 DK-5000 Odense C, Denmark.
Abstract:
Peri-therapeutic (124)I-PET/CT is of interest as guidance for radioiodine therapy. Unfortunately, image quality is complicated by dead time effects and increased random coincidence rates from high (131)I-activities. A series of phantom experiments with clinically relevant (124)I/(131)I-activities were performed on a clinical PET/CT-system. Noise equivalent count rate (NECR) curves and quantitation accuracy were determined from repeated scans performed over several weeks on a decaying NEMA NU-2 1994 cylinder phantom initially filled with 25 MBq (124)I and 1250 MBq (131)I. Six spherical inserts with diameters 10-37 mm were filled with (124)I (0.45 MBq ml(-1)) and (131)I (22 MBq ml(-1)) and placed inside the background of the NEMA/IEC torso phantom. Contrast recovery, background variability and the accuracy of scatter and attenuation corrections were assessed at sphere-to-background activity ratios of 20, 10 and 5. Results were compared to pure (124)I-acquisitions. The quality of (124)I-PET images in the presence of high (131)I-activities was good and image quantification unaffected except at very high count rates. Quantitation accuracy and contrast recovery were uninfluenced at (131)I-activities below 1000 MBq, whereas image noise was slightly increased. The NECR peaked at 550 MBq of (131)I, where it was 2.8 times lower than without (131)I in the phantom. Quantitative peri-therapeutic (124)I-PET is feasible.
Related Concept Videos
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
![PET Imaging of Neuroinflammation Using [11C]DPA-713 in a Mouse Model of Ischemic Stroke](/_next/image?url=https%3A%2F%2Fcloudfront.jove.com%2FCDNSource%2Fteasers%2F57243.jpg&w=3840&q=50)
![Autoradiographic Measurements of [14C]-Iodoantipyrine in Rat Brain Following Central Post-Stroke Pain](/_next/image?url=https%3A%2F%2Fcloudfront.jove.com%2FCDNSource%2Fteasers%2F53947.jpg&w=3840&q=50)