[Is There Really Agreement between Rebound and Goldmann Applanation Tonometry Methods? Results of a Systematic Review
D Sagri1, C-C Lösche1, B-B Bestges1
1Augenklinik, Ev. Krankenhaus, Mülheim an der Ruhr.
Background:
After its introduction in 2003 the iCare® rebound tonometry has gained wide acceptance, mostly as a result of immediate method comparison trials showing high concordance with the Goldmann applanation tonometry (GAT) as a reference method. The objective of this systemic review was the synopsis of the current literature as a rationale of a concordance evaluation between the iCare® rebound and the Goldmann applanation tonometry methods.
Methods:
The PubMed database was searched for Anglo-American and German publications comparing intraindividually the two tonometry methods and having been published during the period 01/2005 to 08/2014. The primary endpoint of the review was the reported IOD deviation [mmHg] between the two devices; for each trial, this primary endpoint was parameterised in terms of the "mean deviation" as well as the "relative frequency [%] of measurements with an intraindividual deviation of ≥ ± 3 mmHg". A total of 33 published method comparison studies concerning the iCare TA01i device were included, 17 of them being published between 01/2009 and 08/2014. The number of analysed eyes ranged between 28 and 445; 17 of the 33 studies reported more than 100 examined eyes. 7 of the 33 studies included only healthy eyes.
Results:
Only 10 out of the 33 studies reported a mean deviation of more than ± 1.5 mmHg, 7 of these were published between 01/2009 and 08/2014. Only 12 of the 33 studies reported the relative frequency of intraindividual deviations ≥ ± 3 mmHg, 7 of them reporting a frequency > 20 % (with a maximum of 51 %), with higher frequencies being derived from samples showing higher IOD levels according to the GAT reference.
Conclusion:
As concluded from the current literature the iCare® rebound and the Goldmann applanation tonometry methods cannot be considered exchangable.
Related Concept Videos
Assessment of blood pressure in brachial artery(two-step method)
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Pre-Procedural Guidelines for Assessing Blood Pressure