Related Experiment Video
Updated: Apr 8, 2026

Software for Analysis of Heart Rate and Blood Pressure Time-series Data from the Valsalva Maneuver
Published on: June 27, 2025
Validation of photoplethysmography as a method to detect heart rate during rest and exercise
David K Spierer1, Zohn Rosen, Leib L Litman
1Division of Athletic Training, Health and Exercise Science, Long Island University Brooklyn , Brooklyn, NY , USA .
Abstract:
Despite their enhanced marketplace visibility, validity of wearable photoplethysmographic heart rate monitoring is scarce. Forty-seven healthy participants performed seven, 6-min exercise bouts and completed a valid skin type scale. Participants wore an Omron HR500U (OHR) and a Mio Alpha (MA), two commercial wearable photoplethysmographic heart rate monitors. Data were compared to a Polar RS800CX (PRS). Means and error were calculated between devices using minutes 2-5. Compared to PRS, MA data was significantly different in walking, biking (2.41 ± 3.99 bpm and 3.26 ± 11.38 bpm, p < 0.05) and weight lifting (23.30 ± 31.94 bpm, p < 0.01). OHR differed from PRS in walking (4.95 ± 7.53 bpm, p < 0.05) and weight lifting (4.67 ± 8.95 bpm, p < 0.05). MA during elliptical, stair climbing and biking conditions demonstrated a strong correlation between jogging speed and error (r = 0.55, p < 0.0001), and showed differences in participants with less photosensitive skin.
More Related Videos
08:12Calculating Heart Rate Variability from ECG Data from Youth with Cerebral Palsy During Active Video Game Sessions
Published on: June 5, 2019
08:22Author Spotlight: Advancing the Study of Brain-Heart Interplay with a Comprehensive EEGLAB Plugin for Multimodal Signal Analysis
Published on: April 26, 2024
Related Concept Videos
Exercise Stress Test
Exercise stress testing, commonly known as a treadmill test, is a noninvasive procedure used to evaluate cardiovascular function and diagnose heart conditions.
Definition
An exercise stress test measures the heart's response to exertion using a treadmill or stationary bicycle. Chest electrodes record the heart's electrical activity through an ECG, and blood pressure is monitored regularly.
Purposes
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and...
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Special considerations while measuring pulse
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...