Related Experiment Video
Updated: Apr 8, 2026

Multi-Tracer Studies of Brain Oxygen and Glucose Metabolism Using a Time-of-Flight Positron Emission Tomography-Computed Tomography Scanner
Published on: June 7, 2024
Optimizing light transport in scintillation crystals for time-of-flight PET: an experimental and optical Monte Carlo
Eric Berg1, Emilie Roncali1, Simon R Cherry2
1Department of Biomedical Engineering, University of California, Davis, One Shields Avenue, Davis, CA, 95616, USA ; These authors contributed equally.
Abstract:
Achieving excellent timing resolution in gamma ray detectors is crucial in several applications such as medical imaging with time-of-flight positron emission tomography (TOF-PET). Although many factors impact the overall system timing resolution, the statistical nature of scintillation light, including photon production and transport in the crystal to the photodetector, is typically the limiting factor for modern scintillation detectors. In this study, we investigated the impact of surface treatment, in particular, roughening select areas of otherwise polished crystals, on light transport and timing resolution. A custom Monte Carlo photon tracking tool was used to gain insight into changes in light collection and timing resolution that were observed experimentally: select roughening configurations increased the light collection up to 25% and improved timing resolution by 15% compared to crystals with all polished surfaces. Simulations showed that partial surface roughening caused a greater number of photons to be reflected towards the photodetector and increased the initial rate of photoelectron production. This study provides a simple method to improve timing resolution and light collection in scintillator-based gamma ray detectors, a topic of high importance in the field of TOF-PET. Additionally, we demonstrated utility of our Monte Carlo simulation tool to accurately predict the effect of altering crystal surfaces on light collection and timing resolution.
More Related Videos
06:28Visualization of Low-Level Gamma Radiation Sources Using a Low-Cost, High-Sensitivity, Omnidirectional Compton Camera
Published on: January 30, 2020
10:18Dynamic Pore-scale Reservoir-condition Imaging of Reaction in Carbonates Using Synchrotron Fast Tomography
Published on: February 21, 2017
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET