Diagnostic Accuracy of Blood Glucose Measurements in Detecting Venous Compromise in Flaps
Muhammad Mustehsan Bashir1, Zahid Tayyab, Saira Afzal
1Department of Plastic surgery, KEMU, Mayo Hospital, Lahore, Pakistan.
Abstract:
Due to limitations of the current methods for monitoring flap circulation, newer methods with better diagnostic accuracy are needed. A drop in blood glucose levels within flap is a simple method that can be widely used; however, this method has been examined only in small cohorts. The objective of this study was to determine the diagnostic accuracy of blood glucose measurements within flaps in early detection of venous compromise. We sampled 127 pedicled and free flaps, including replants, performed on patients between 12 and 60 years of age. Within flap blood glucose measurements were performed using pinprick and a blood glucose meter at 0, 6, 12, 24 and 48 hours after operation. Daily examination for clinical signs of venous compromise was used to determine flap viability for up to 7th day after operation. Of the 127 flaps, 76 (60%) were performed on men and the mean age ± standard deviation of the patients was 35.8 ± 12.1 years. A cut-off value of 62 mg/dL was determined using a receiver operating characteristic curve. Using this cut-off value, the sensitivity and positive predictive values of within flap blood glucose for determining venous compromise were 90% and 91%, respectively, whereas the specificity and negative predictive values were 78% and 76%, respectively. The overall diagnostic accuracy of within flap blood glucose was 87%. We conclude that blood glucose measurement within flap has acceptable diagnostic accuracy and should be used for early detection of venous compromise.
More Related Videos
Related Concept Videos
Venous Thrombosis II: Clinical Manifestations and Diagnostic Studies
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
Blood Studies I: ABG and VBG
Arterial Blood Gas (ABG)
Arterial Blood Gas (ABG) studies are crucial for assessing the lungs' ability to supply oxygen and remove carbon dioxide, reflecting the patient's ventilation status. They also help understand the kidneys' capacity to...
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation