Related Experiment Video
Updated: Apr 8, 2026

High-throughput Detection Method for Influenza Virus
Published on: February 4, 2012
Non-Invasive Optical Sensor Based Approaches for Monitoring Virus Culture to Minimize BSL3 Laboratory Entry
Viswanath Ragupathy1, Mohan Kumar Hayuri Giri Setty2, Yordan Kostov3
1LMV/DETTD/OBRR/CBER/FDA, Silver Spring, MD 20993, USA. viswanath.ragupathy@fda.hhs.gov.
Abstract:
High titers of infectious viruses for vaccine and diagnostic reference panel development are made by infecting susceptible mammalian cells. Laboratory procedures are strictly performed in a Bio-Safety Level-3 (BSL3) laboratory and each entry and exit involves the use of disposable Personnel Protective Equipment (PPE) to observe cell culture conditions. Routine PPE use involves significant recurring costs. Alternative non-invasive optical sensor based approaches to remotely monitor cell culture may provide a promising and cost effective approach to monitor infectious virus cultures resulting in lower disruption and costs. We report here the monitoring of high titer cultures of Human Immunodeficiency Virus-1 (HIV-1) and Herpes Simplex Virus-2 (HSV-2) remotely with the use of optical oxygen sensors aseptically placed inside the cell culture vessel. The replacement of culture media for cell and virus propagation and virus load monitoring was effectively performed using this fluorescent sensor and resulted in half the number of visits to the BSL3 lab (five versus ten).
Insights
This study introduces non-invasive optical oxygen sensors for monitoring infectious virus cultures in Bio-Safety Level-3 (BSL3) labs. This method reduces lab visits and costs associated with personal protective equipment (PPE) for cell culture monitoring.
Area of Science:
- Virology
- Biotechnology
- Biomedical Engineering
Background:
- High-titer infectious virus cultures are essential for vaccine and diagnostic development.
- Current cell culture monitoring in Bio-Safety Level-3 (BSL3) laboratories requires extensive use of disposable personal protective equipment (PPE), incurring significant recurring costs and labor.
- Non-invasive monitoring methods could reduce costs and disruptions in BSL3 environments.
Purpose of the Study:
- To evaluate the efficacy of non-invasive optical oxygen sensors for remote monitoring of high-titer infectious virus cultures.
- To assess the potential of this technology to reduce costs and laboratory disruptions in BSL3 settings.
Main Methods:
- Aseptically placed optical oxygen sensors were used to remotely monitor cell cultures of Human Immunodeficiency Virus-1 (HIV-1) and Herpes Simplex Virus-2 (HSV-2).
- The sensors facilitated monitoring of cell and virus propagation and culture media replacement.
- The number of BSL3 laboratory entries was compared between sensor-guided and traditional methods.
Main Results:
- Optical oxygen sensors enabled effective remote monitoring of high-titer HIV-1 and HSV-2 cultures.
- The use of sensors streamlined culture media replacement and virus load monitoring.
- The number of required visits to the BSL3 laboratory was reduced by 50% (from ten to five visits).
Conclusions:
- Non-invasive optical oxygen sensors offer a promising, cost-effective alternative for monitoring infectious virus cultures in BSL3 laboratories.
- This approach significantly reduces the need for PPE and minimizes laboratory disruptions.
- Remote monitoring with optical sensors enhances efficiency and safety in viral culture propagation.
Related Concept Videos
Microbial Growth Measurement: Indirect Methods
Microbial Growth Measurement: Direct Methods