Voluntary Breath-hold Technique for Reducing Heart Dose in Left Breast Radiotherapy
Published on: July 3, 2014
Dosimetric evaluation of whole-breast radiation therapy: clinical experience
Ernest Osei1, Johnson Darko2, Andre Fleck3
1Department of Medical Physics, Grand River Regional Cancer Centre, Kitchener, Ontario, Canada; Department of Physics and Astronomy, University of Waterloo, Waterloo, Ontario, Canada; Department of Systems Design, University of Waterloo, Waterloo, Ontario, Canada.
Abstract:
Radiation therapy of the intact breast is the standard therapy for preventing local recurrence of early-stage breast cancer following breast conservation surgery. To improve patient standard of care, there is a need to define a consistent and transparent treatment path for all patients that reduces significance variations in the acceptability of treatment plans. There is lack of consistency among institutions or individuals about what is considered an acceptable treatment plan: target coverage vis-à-vis dose to organs at risk (OAR). Clinical trials usually resolve these issues, as the criteria for an acceptable plan within the trial (target coverage and doses to OAR) are well defined. We developed an institutional criterion for accepting breast treatment plans in 2006 after analyzing treatment data of approximately 200 patients. The purpose of this article is to report on the dosimetric review of 623 patients treated in the last 18 months to evaluate the effectiveness of the previously developed plan acceptability criteria and any possible changes necessary to further improve patient care. The mean patient age is 61.6 years (range: 25.2 to 93.0 years). The mean breast separation for all the patients is 21.0cm (range: 12.4 to 34.9cm), and the mean planning target volume (PTV_eval) (breast volume for evaluation) is 884.0cm(3) (range: 73.6 to 3684.6cm(3)). Overall, 314 (50.4%) patients had the disease in the left breast and 309 (49.6%) had it in the right breast. A total of 147 (23.6%) patients were treated using the deep inspiration breath-hold (DIBH) technique. The mean normalized PTV_eval receiving at least 92% (V92% PD) and 95% (V95% PD) of the prescribed dose (PD) are more than 99% and 97%, respectively, for all patients. The mean normalized PTV_eval receiving at least 105% (V105% PD) of the PD is less than 1% for all groups. The mean homogeneity index (HI), uniformity index (UI), and conformity index (CI) for the PTV_eval are 0.09 (range: 0.05 to 0.15), 1.07 (range: 0.46 to 1.11), and 0.98 (range: 0.92 to 1.0), respectively. Our data confirm the significant advantage of using DIBH to reduce heart dose when compared with the free-breathing technique. The p values analyses of the results for the V5Gy, V10Gy, V15Gy, V20Gy, and V30Gy for the heart comparing DIBH and free-breathing techniques are well less than 0.05 (i.e., p < 0.05). However, similar analyses for the lung give values greater than 0.05 (i.e., p > 0.05), indicating that there is no significant difference in lung dose comparing the 2 treatment techniques.
More Related Videos
08:34Proton Therapy Delivery and Its Clinical Application in Select Solid Tumor Malignancies
Published on: February 6, 2019
09:49A Whole Body Dosimetry Protocol for Peptide-Receptor Radionuclide Therapy PRRT: 2D Planar Image and Hybrid 2D+3D SPECT/CT Image Methods
Published on: April 24, 2020