Related Experiment Video
Updated: Apr 8, 2026

Detection of Architectural Distortion in Prior Mammograms via Analysis of Oriented Patterns
Published on: August 30, 2013
Improvement in Detection of Wrong-Patient Errors When Radiologists Include Patient Photographs in Their
Srini Tridandapani1,2, Kevin Olsen3, Pamela Bhatti4
1Department of Radiology and Imaging Sciences, Winship Cancer Institute, Emory University School of Medicine, 1701 Uppergate Drive NE, Atlanta, GA, 30322, USA. stridan@emory.edu.
Abstract:
This study was conducted to determine whether facial photographs obtained simultaneously with radiographs improve radiologists' detection rate of wrong-patient errors, when they are explicitly asked to include the photographs in their evaluation. Radiograph-photograph combinations were obtained from 28 patients at the time of portable chest radiography imaging. From these, pairs of radiographs were generated. Each unique pair consisted of one new and one old (comparison) radiograph. Twelve pairs of mismatched radiographs (i.e., pairs containing radiographs of different patients) were also generated. In phase 1 of the study, 5 blinded radiologist observers were asked to interpret 20 pairs of radiographs without the photographs. In phase 2, each radiologist interpreted another 20 pairs of radiographs with the photographs. Radiologist observers were not instructed about the purpose of the photographs but were asked to include the photographs in their review. The detection rate of mismatched errors was recorded along with the interpretation time for each session for each observer. The two-tailed Fisher exact test was used to evaluate differences in mismatch detection rates between the two phases. A p value of <0.05 was considered significant. The error detection rates without (0/20 = 0%) and with (17/18 = 94.4%) photographs were different (p = 0.0001). The average interpretation times for the set of 20 radiographs were 26.45 (SD 8.69) and 20.55 (SD 3.40) min, for phase 1 and phase 2, respectively (two-tailed Student t test, p = 0.1911). When radiologists include simultaneously obtained photographs in their review of portable chest radiographs, there is a significant improvement in the detection of labeling errors. No statistically significant difference in interpretation time was observed. This may lead to improved patient safety without affecting radiologists' throughput.
Related Concept Videos
Radiological Investigation I: X-ray and CT
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
X-ray Imaging
Guidelines and Strategies for Safe Computer Charting
Maintain Confidentiality and Security:
Errors occurring during blood pressure monitoring
Several factors...