Related Experiment Video
Updated: Apr 7, 2026

Concurrent EEG and Functional MRI Recording and Integration Analysis for Dynamic Cortical Activity Imaging
Published on: June 30, 2018
Exploitation of temporal redundancy in compressed sensing reconstruction of fMRI studies with a prior-based algorithm
C Chavarrías1, J F P J Abascal1, P Montesinos2
1Departamento de Bioingeniería e Ingeniería Aeroespacial, Universidad Carlos III de Madrid, Avda. de la Universidad 30, Leganés, Madrid 28911, Spain and Instituto de Investigación Sanitaria Gregorio Marañón, Doctor Esquerdo 46, Madrid 28007, Spain.
Purpose:
Compressed sensing is a technique used to accelerate magnetic resonance imaging (MRI) acquisition without compromising image quality. While it has proven particularly useful in dynamic imaging procedures such as cardiac cine, very few authors have applied it to functional magnetic resonance imaging (fMRI). The purpose of the present study was to check whether the prior image constrained compressed sensing (PICCS) algorithm, which is based on an available prior image, can improve the statistical maps in fMRI better than other strategies that also exploit temporal redundancy.
Methods:
PICCS was compared to spatiotemporal total variation (TTV) and k-t FASTER, since they have already demonstrated high performance and robustness in other MRI applications, such as cardiac cine MRI and resting state fMRI, respectively. The prior image for PICCS was the average of all undersampled data. Both PICCS and TTV were solved using the split Bregman formulation. K-t FASTER algorithm relies on matrix completion to reconstruct the undersampled k-spaces. The three algorithms were evaluated using two datasets with high and low signal-to-noise ratio (SNR)-BOLD contrast-acquired in a 7 T preclinical MRI scanner and retrospectively undersampled at various rates (i.e., acceleration factors). The authors evaluated their performance in terms of the sensitivity/specificity of BOLD detection through receiver operating characteristic curves and by visual inspection of the statistical maps.
Results:
With high SNR studies, PICCS performed similarly to the state-of-the-art algorithms TTV and k-t FASTER and provided consistent BOLD signal at the ROI. In scenarios with low SNR and high acceleration factors, PICCS still provided consistent maps and higher sensitivity/specificity than TTV, whereas k-t FASTER failed to provide significant maps.
Conclusions:
The authors performed a comparison between three reconstructions (PICCS, TTV, and k-t FASTER) that exploit temporal redundancy in fMRI. The prior-based algorithm, PICCS, preserved BOLD activation and sensitivity/specificity better than TTV and k-t FASTER in noisy scenarios. The PICCS algorithm can potentially reach an acceleration factor of ×8 and still provide BOLD contrast in the ROI with an area under the curve over 0.99.
More Related Videos
08:19Simultaneous Data Collection of fMRI and fNIRS Measurements Using a Whole-Head Optode Array and Short-Distance Channels
Published on: October 20, 2023
07:12Using Informational Connectivity to Measure the Synchronous Emergence of fMRI Multi-voxel Information Across Time
Published on: July 1, 2014