Related Experiment Video
Updated: Apr 7, 2026

Software for Analysis of Heart Rate and Blood Pressure Time-series Data from the Valsalva Maneuver
Published on: June 27, 2025
'Errors' and omissions in paper-based early warning scores: the association with changes in vital signs--a database
David A Clifton1, Lei Clifton2, Dona-Maria Sandu1
1Institute of Biomedical Engineering, University of Oxford, Oxford, UK.
Objectives:
To understand factors associated with errors using an established paper-based early warning score (EWS) system. We investigated the types of error, where they are most likely to occur, and whether 'errors' can predict subsequent changes in patient vital signs.
Methods:
Retrospective analysis of prospectively collected early warning system database from a single large UK teaching hospital.
Results:
16,795 observation sets, from 200 postsurgical patients, were collected. Incomplete observation sets were more likely to contain observations which should have led to an alert than complete observation sets (15.1% vs 7.6%, p<0.001), but less likely to have an alerting score correctly calculated (38.8% vs 30.0%, p<0.001). Mis-scoring was much more common when leaving a sequence of three or more consecutive observation sets with aggregate scores of 0 (55.3%) than within the sequence (3.0%, p<0.001). Observation sets that 'incorrectly' alerted were more frequently followed by a correctly alerting observation set than error-free non-alerting observation sets (14.7% vs 4.2%, p<0.001). Observation sets that 'incorrectly' did not alert were more frequently followed by an observation set that did not alert than error-free alerting observation sets (73.2% vs 45.8%, p<0.001).
Conclusions:
Missed alerts are particularly common in incomplete observation sets and when a patient first becomes unstable. Observation sets that 'incorrectly' alert or 'incorrectly' do not alert are highly predictive of the next observation set, suggesting that clinical staff detect both deterioration and improvement in advance of the EWS system by using information not currently encoded within it. Work is urgently needed to understand how best to capture this information.
More Related Videos
05:51Assessing the Accuracy of Fitness Smartwatch Data for Cardiovascular and Physical Activity Monitoring: A Validation Study in Digital Health
Published on: February 21, 2025
08:12Calculating Heart Rate Variability from ECG Data from Youth with Cerebral Palsy During Active Video Game Sessions
Published on: June 5, 2019
Related Concept Videos
Errors occurring during blood pressure monitoring
Several factors...
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Introduction to Vital Signs
Vital signs help healthcare professionals assess an individual's well-being and detect any functional changes...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Documentation of Nursing Diagnosis
In some settings, data-driven computerized decision support systems are in place, allowing for more accurate nursing diagnoses. The database within one of these systems includes diagnostic labels defining characteristics, activities, and indicators for nursing. A nurse enters...
Measurement of Blood Pressure