Related Experiment Video
Updated: Apr 7, 2026

In Vivo, Percutaneous, Needle Based, Optical Coherence Tomography of Renal Masses
Published on: March 30, 2015
Comparison of 2 Computed Tomography-based Methods to Estimate Preoperative and Postoperative Renal Parenchymal Volume
Nidhi Sharma1, Zhiling Zhang2, Maria C Mir3
1Imaging Institute, Cleveland Clinic, Cleveland, OH.
Objective:
To compare freehand scripting and semiautomated renal parenchymal volume measurements on preoperative or postoperative computed tomography scans and assess relationships between parenchymal volume loss and functional changes within the operated kidney after partial nephrectomy (PN).
Materials And Methods:
Fifty patients (16 solitary kidneys, 34 bilateral kidneys) with renal tumors managed by PN with necessary studies for analysis were included. Freehand scripting and semiautomated threshold-based analysis were performed before and 4-12 months after PN to obtain preoperative normal parenchymal volumes, projected residual parenchymal volumes, and actual postoperative volumes. Glomerular filtration rate was determined by the Modification of Diet in Renal Disease 2 equation along with nuclear renal scan to provide split function for patients with 2 kidneys. Limits of agreement and Bland-Altman analyses were performed. The relationship between the amount of vascularized parenchyma preserved and renal function saved was correlated for each measurement method using Pearson correlation.
Results:
The semiautomated method yielded estimates that were higher than freehand scripting by a mean of 14 cm(3) for estimation of preoperative normal parenchymal volume, 21 cm(3) for projected residual parenchymal volume, and 9 cm(3) for actual postoperative parenchymal volume. For the semiautomated method, correlation between the amount of normal parenchyma preserved and renal function saved was 0.52 (95% confidence interval [CI], 0.28-0.69; P <.001), and for the scripting method, correlation was 0.60 (95% CI, 0.39-0.76; P <.001).
Conclusion:
Semiautomated and freehand scripting measurements of parenchymal volumes were relatively consistent before and after PN, although the semiautomated approach tended to yield volumes that were approximately 5%-10% higher on average. Measurement of parenchymal volume changes by both approaches correlated significantly with functional changes after PN.
Related Concept Videos
Imaging Studies III: Computed Tomography
Renal Drug Clearance: Comparison Between Renal Excretion Methods
Renal clearance is often associated with the renal glomerular filtration rate (GFR), which represents the rate at which plasma is filtered through the glomeruli in the kidney. When drug reabsorption is minimal and there is no active secretion, renal clearance is closely related to the...
Imaging Studies I: Kidney, Ureter, and Bladder Studies
Imaging Studies VII: Vascular Imaging
Determination of Renal Drug Clearance: Graphical and Midpoint Methods
The graphical method involves plotting the rate of drug excretion in urine against the plasma drug concentration. By analyzing the graph, the clearance can be calculated and obtained. Drugs rapidly excreted by the kidneys exhibit a...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...

