A New Single Chamber Implantable Defibrillator with Atrial Sensing: A Practical Demonstration of Sensing and Ease of Implantation
Published on: February 28, 2012
Implantation of a cardiac resynchronization therapy-defibrillator device in a patient with persistent left superior
İlyas Atar1, Emir Karaçağlar1, Emre Özçalık1
1Department of Cardiology, Baskent University Faculty of Medicine Hospital, Ankara, Turkey.
Insights
A persistent left superior vena cava (PLSVC) can complicate cardiac device implantation. This case demonstrates a successful strategy for implanting a resynchronization therapy-defibrillator device despite the presence of PLSVC.
Area of Science:
- Cardiology
- Medical Devices
- Anatomy
Background:
- Persistent left superior vena cava (PLSVC) is a rare congenital anomaly.
- While often asymptomatic, PLSVC can present challenges during cardiovascular procedures.
- Cardiac device implantation, such as CRT-D, requires precise lead placement.
Observation:
- An 82-year-old male patient with heart failure (EF 20%) was diagnosed with PLSVC.
- The PLSVC drained into an enlarged right atrium via a dilated coronary sinus.
- This anatomical variation posed a potential obstacle for device lead insertion.
Findings:
- A novel approach was used to navigate the PLSVC.
- An active-fixation right ventricular lead was successfully advanced through the PLSVC to the apex.
- Atrial and coronary sinus leads were optimally positioned, enabling successful CRT-D implantation.
Implications:
- This case highlights a feasible technique for CRT-D implantation in patients with PLSVC.
- Successful implantation can improve outcomes for heart failure patients with complex anatomy.
- Awareness of PLSVC variations is crucial for interventional cardiologists.
Abstract:
Presence of a persistent left superior vena cava (PLSVC) is generally clinically asymptomatic and discovered incidentally during central venous catheterization. However, PLSVC may cause technical difficulties during cardiac device implantation. An 82-year-old man with heart failure symptoms and an ejection fraction (EF) of 20% was scheduled for resynchronization therapy-defibrillator device (CRT-D) implantation. A PLSVC draining via a dilated coronary sinus into an enlarged right atrium was diagnosed. First, an active-fixation right ventricular lead was inserted into the right atrium through the PLSVC. The stylet was preshaped to facilitate its passage to the right ventricular apex. An atrial lead was positioned on the right atrium free wall, and an over-the-wire coronary sinus lead deployed to a stable position. CRT-D implantation procedure was successfully completed.
More Related Videos
12:45Benefits of Cardiac Resynchronization Therapy in an Asynchronous Heart Failure Model Induced by Left Bundle Branch Ablation and Rapid Pacing
Published on: December 11, 2017
07:41Insertion, Maintenance, and Removal of the Percutaneous Dual Lumen Cannula Right Ventricular Assist Device
Published on: July 20, 2022
Related Concept Videos
Cardiomyopathy V: Interprofessional Care
Cardiomyopathy II: Dilated Cardiomyopathy
Cardiac Catheterization III: Left Heart Catheterization
Cardiac Catheterization II: Right Heart Catheterization
Heart Failure VI: Adjunct Therapies
Cardiac Catheterization IV: Nursing Management