Related Experiment Video
Updated: Apr 7, 2026

Human Mesenchymal Stem Cell Processing for Clinical Applications Using a Closed Semi-Automated Workflow
Published on: March 17, 2023
Validation of shortened 2-day sterility testing of mesenchymal stem cell-based therapeutic preparation on an
Daniel Lysák1, Monika Holubová2, Tamara Bergerová3
1Department of Hematology and Oncology, Medical School and Teaching Hospital in Plzen, Charles University in Prague, Alej Svobody 80, 304 60, Plzen, Czech Republic. lysak@fnplzen.cz.
Abstract:
Cell therapy products represent a new trend of treatment in the field of immunotherapy and regenerative medicine. Their biological nature and multistep preparation procedure require the application of complex release criteria and quality control. Microbial contamination of cell therapy products is a potential source of morbidity in recipients. The automated blood culture systems are widely used for the detection of microorganisms in cell therapy products. However the standard 2-week cultivation period is too long for some cell-based treatments and alternative methods have to be devised. We tried to verify whether a shortened cultivation of the supernatant from the mesenchymal stem cell (MSC) culture obtained 2 days before the cell harvest could sufficiently detect microbial growth and allow the release of MSC for clinical application. We compared the standard Ph. Eur. cultivation method and the automated blood culture system BACTEC (Becton Dickinson). The time to detection (TTD) and the detection limit were analyzed for three bacterial and two fungal strains. The Staphylococcus aureus and Pseudomonas aeruginosa were recognized within 24 h with both methods (detection limit ~10 CFU). The time required for the detection of Bacillus subtilis was shorter with the automated method (TTD 10.3 vs. 60 h for 10-100 CFU). The BACTEC system reached significantly shorter times to the detection of Candida albicans and Aspergillus brasiliensis growth compared to the classical method (15.5 vs. 48 and 31.5 vs. 48 h, respectively; 10-100 CFU). The positivity was demonstrated within 48 h in all bottles, regardless of the size of the inoculum. This study validated the automated cultivation system as a method able to detect all tested microorganisms within a 48-h period with a detection limit of ~10 CFU. Only in case of B. subtilis, the lowest inoculum (~10 CFU) was not recognized. The 2-day cultivation technique is then capable of confirming the microbiological safety of MSC and allows their timely release for clinical application.
More Related Videos
10:30Mesenchymal Stromal Cell Culture and Delivery in Autologous Conditions: A Smart Approach for Orthopedic Applications
Published on: December 8, 2016
11:05Production and Administration of Therapeutic Mesenchymal Stem/Stromal Cell MSC Spheroids Primed in 3-D Cultures Under Xeno-free Conditions
Published on: March 18, 2017