Related Experiment Video
Updated: Apr 7, 2026

Measuring 3D In-vivo Shoulder Kinematics using Biplanar Videoradiography
Published on: March 12, 2021
Testing the assumption in ergonomics software that overall shoulder strength can be accurately calculated by treating
Joanne N Hodder1, Nicholas J La Delfa2, Jim R Potvin2
1Department of Kinesiology, McMaster University, Hamilton, ON, Canada; School of Applied Health Sciences, Sheridan College, Brampton, ON, Canada.
Abstract:
To predict shoulder strength, most current ergonomics software assume independence of the strengths about each of the orthopedic axes. Using this independent axis approach (IAA), the shoulder can be predicted to have strengths as high as the resultant of the maximum moment about any two or three axes. We propose that shoulder strength is not independent between axes, and propose an approach that calculates the weighted average (WAA) between the strengths of the axes involved in the demand. Fifteen female participants performed maximum isometric shoulder exertions with their right arm placed in a rigid adjustable brace affixed to a tri-axial load cell. Maximum exertions were performed in 24 directions, including four primary directions, horizontal flexion-extension, abduction-adduction, and at 15° increments in between those axes. Moments were computed and comparisons made between the experimentally collected strengths and those predicted by the IAA and WAA methods. The IAA over-predicted strength in 14 of 20 non-primary exertions directions, while the WAA underpredicted strength in only 2 of these directions. Therefore, it is not valid to assume that shoulder axes are independent when predicting shoulder strengths between two orthopedic axes, and the WAA is an improvement over current methods for the posture tested.
More Related Videos
Related Concept Videos
General Case of Eccentric Axial Loading
Consider a member subjected to equal and opposite forces that are applied along a line that does not coincide with the member's neutral axis. In unsymmetrical...
Eccentric Axial Loading in a Plane of Symmetry
Unsymmetric Bending - Angle of Neutral Axis
When a bending moment is applied at an angle θ concerning the vertical axis of a symmetrical member, it can be resolved into components along the member's principal...
Space Trusses: Problem Solving
Consider a tripod consisting of a tetrahedral space truss with a ball-and-socket joint at C. Suppose the height and lengths of the horizontal and vertical...
Frames: Problem Solving II
Muscles of the Shoulder
Anterior Thoracic Muscles
The anterior thoracic muscles include the serratus anterior, subclavius, and...

