Related Experiment Video
Updated: Apr 7, 2026

Conducting Respiratory Oscillometry in an Outpatient Setting
Published on: April 8, 2022
Pediatric OSAS: Oximetry can provide answers when polysomnography is not available
Athanasios Kaditis1, Leila Kheirandish-Gozal2, David Gozal2
1Pediatric Pulmonology Unit, Sleep Disorders Laboratory, First Department of Pediatrics, University of Athens School of Medicine and Aghia Sophia Children's Hospital, Athens, Greece.
Abstract:
Overnight polysomnography is the gold standard tool for the diagnosis of obstructive sleep apnea syndrome (OSAS) in habitually snoring children, but it is expensive and not always available. Nocturnal oximetry has been proposed as an abbreviated and low-cost testing modality for the diagnosis of OSAS. In this systematic review, 25 original articles were evaluated to: (i) summarize reference values of nocturnal oximetry parameters in healthy children; (ii) identify abnormal oximetry patterns that predict OSAS in habitually snoring children; (iii) delineate abnormalities in oximetry that can predict responses to treatment interventions for OSAS and potential complications. Nocturnal SpO2 drops <90%, more than two clusters of desaturation events (≥4%) and oxyhemoglobin desaturation (≥4%) index (ODI4) >2.2 episodes/h are unusual in children without OSAS. At least three clusters of desaturation events, and at least three SpO2 drops below 90% in a nocturnal oximetry recording are indicative of moderate-to-severe OSAS. An ODI4 >2 episodes/h combined with OSAS symptoms also exhibits high positive predictive value for apnea-hypopnea index >1 episode/h. Children without clusters of desaturation events have low risk of major respiratory complications following adenotonsillectomy. Thus, nocturnal oximetry emerges as a valuable tool that can facilitate treatment decisions when polysomnography is not available.
Related Concept Videos
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Respiratory Assessment: Purpose and Indications
Objectives and Importance:
The primary goal of respiratory assessment is to evaluate patients at early risk of clinical deterioration. Since respiratory distress often precedes other signs of declining health, breathing patterns and sounds become a...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask