Automated Microbial Diagnostics01:24

Automated Microbial Diagnostics

45
Automated diagnostic analyzers have transformed clinical microbiology by providing rapid and reliable methods for pathogen identification and antibiotic susceptibility testing. Among these systems, the Vitek 2 is widely used because it automates the traditionally labor-intensive processes of microbial identification (ID) and antibiotic susceptibility testing (AST), delivering standardized and timely results that are essential for effective patient care.Microbial Identification with ID CardsThe...
45

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

<i>Letter:</i> Low Uptake of HIV Pre-Exposure Prophylaxis Despite Pharmacist-Managed Services in a Midwestern Federally Qualified Health Center.

AIDS patient care and STDs·2026
Same author

Talent identification and development strategies in elite women's soccer: a pan-European perspective.

Science & medicine in football·2024
Same author

A qualitative study of the transition to employment of former university students on the autism spectrum from Australia and New Zealand.

International journal of developmental disabilities·2024
Same author

Axon-derived PACSIN1 binds to the Schwann cell survival receptor, LRP1, and transactivates TrkC to promote gliatrophic activities.

Glia·2024
Same author

Emotion regulation in children (ERiC): A protocol for a randomised clinical trial to evaluate the clinical and cost effectiveness of Mentalization Based Treatment (MBT) vs Treatment as Usual for school-age children with mixed emotional and behavioural difficulties.

PloS one·2023
Same author

Low-Grade Fumarate Hydratase-Deficient Renal Cell Carcinoma in a 30-Year-Old Female.

International journal of surgical pathology·2021

Related Experiment Video

Updated: Apr 7, 2026

Integration of Wet and Dry Bench Processes Optimizes Targeted Next-generation Sequencing of Low-quality and Low-quantity Tumor Biopsies
13:24

Integration of Wet and Dry Bench Processes Optimizes Targeted Next-generation Sequencing of Low-quality and Low-quantity Tumor Biopsies

Published on: April 11, 2016

12.4K

Improved internal control for molecular diagnosis assays.

T Vinayagamoorthy1, Danielle Maryanski1, Dilanthi Vinayagamoorthy1

  • 1MultiGEN Diagnostics LLC, 854 Pargon Way, Rock Hill, SC 29730, United States.

Methodsx
|July 8, 2015
PubMed
Summary

The IC-Code platform offers a true internal control for molecular diagnostics, ensuring accurate DNA amplification and identification by using identical annealing sequences for both the control and analyte. This reduces false negatives and positives, improving diagnostic reliability.

Keywords:
AnalyteIC-CodeMultiplex PCRNucleic acid amplification testPb2aSanger sequencingTrue negative control for PCR amplification and DNA sequencing coupled analysis

More Related Videos

Postmortem Diagnosis of Rabies in Animals by the Updated, Multiplexed LN34 Real-Time Reverse Transcription-Polymerase Chain Reaction Assay
09:54

Postmortem Diagnosis of Rabies in Animals by the Updated, Multiplexed LN34 Real-Time Reverse Transcription-Polymerase Chain Reaction Assay

Published on: May 2, 2025

901
Detection and Monitoring of Tumor Associated Circulating DNA in Patient Biofluids
06:53

Detection and Monitoring of Tumor Associated Circulating DNA in Patient Biofluids

Published on: June 8, 2019

9.3K

Related Experiment Videos

Last Updated: Apr 7, 2026

Integration of Wet and Dry Bench Processes Optimizes Targeted Next-generation Sequencing of Low-quality and Low-quantity Tumor Biopsies
13:24

Integration of Wet and Dry Bench Processes Optimizes Targeted Next-generation Sequencing of Low-quality and Low-quantity Tumor Biopsies

Published on: April 11, 2016

12.4K
Postmortem Diagnosis of Rabies in Animals by the Updated, Multiplexed LN34 Real-Time Reverse Transcription-Polymerase Chain Reaction Assay
09:54

Postmortem Diagnosis of Rabies in Animals by the Updated, Multiplexed LN34 Real-Time Reverse Transcription-Polymerase Chain Reaction Assay

Published on: May 2, 2025

901
Detection and Monitoring of Tumor Associated Circulating DNA in Patient Biofluids
06:53

Detection and Monitoring of Tumor Associated Circulating DNA in Patient Biofluids

Published on: June 8, 2019

9.3K

Area of Science:

  • Molecular Biology
  • Biotechnology
  • Medical Diagnostics

Background:

  • Molecular diagnostics rely on DNA amplification and identification.
  • Current amplification controls like housekeeping genes lack true internal control due to non-identical annealing conditions.
  • This can lead to inaccurate results, including false negatives.

Purpose of the Study:

  • To introduce the IC-Code platform technology for enhanced molecular diagnostic accuracy.
  • To present a novel internal control system that overcomes limitations of traditional amplification controls.
  • To improve the reliability of molecular diagnostic assays.

Main Methods:

  • The IC-Code platform utilizes identical PCR primer annealing sequences for both the internal control and the analyte.
  • It employs identical sequencing primer annealing sequences for the identification step.
  • DNA sequencing analysis is used for precise analyte identification.

Main Results:

  • The IC-Code platform ensures identical annealing conditions for the internal control and analyte.
  • This design significantly minimizes false negatives and false positives.
  • The lower limit of detection can be precisely set by adjusting the internal control concentration.

Conclusions:

  • The IC-Code platform provides a true internal control for molecular diagnostics.
  • This technology enhances the accuracy and reliability of DNA amplification and identification.
  • It offers a robust solution for reducing diagnostic errors.