Background:
Dynamic indices, such as pulse pressure variation (PPV), are inaccurate predictors of fluid responsiveness in mechanically ventilated patients with low tidal volume. This study aimed to test whether changes in continuous cardiac index (CCI), PPV, and stroke volume variation (SVV) after a mini-fluid challenge (100 ml of fluid during 1 min) could predict fluid responsiveness in these patients.
Methods:
We prospectively studied 49 critically ill, deeply sedated, and mechanically ventilated patients (tidal volume <8 ml kg(-1) of ideal body weight) without cardiac arrhythmias, in whom a fluid challenge was indicated because of circulatory failure. The CCI, SVV (PiCCO™; Pulsion), and PPV (MP70™; Philips) were measured before and after 100 ml of colloid infusion during 1 min, and then after the additional infusion of 400 ml during 14 min. Responders were defined as subjects with a ≥15% increase in cardiac index (transpulmonary thermodilution) after the full (500 ml) fluid challenge. Areas under the receiver operating characteristic curves (AUCs) and the grey zones were determined for changes in CCI (ΔCCI100), SVV (ΔSVV100), and PPV (ΔPPV100) after 100 ml fluid challenge.
Results:
Twenty-two subjects were responders. The ΔCCI100 predicted fluid responsiveness with an AUC of 0.78. The grey zone was large and included 67% of subjects. The ΔSVV100 and ΔPPV100 predicted fluid responsiveness with AUCs of 0.91 and 0.92, respectively. Grey zones were small, including ≤12% of subjects for both indices.
Conclusions:
The ΔSVV100 and ΔPPV100 predict fluid responsiveness accurately and better than ΔCCI100 (PiCCO™; Pulsion) in patients with circulatory failure and ventilated with low volumes.
Related Concept Videos
Regulation of Stroke Volume
Preload refers to the degree of stretch on the heart before it contracts. It's analogous to the stretching of a rubber band; the more it's stretched, the more forcefully it snaps back. This concept is encapsulated in the Frank-Starling law of the...
Cardiac Output II: Effect of Stroke Volume on Cardiac Output
Preload
Preload refers to the initial elongation of the cardiac myocytes before contraction and is related to the volume of blood filling the heart at the end of diastole, or end-diastolic volume. The...
Measurement of Blood Pressure
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
Pre-Procedural Guidelines for Assessing Blood Pressure
Cardiac Output and Stroke Volume
In an average resting adult male, the typical cardiac...