Newborn manikin study shows that physicians often fail to detect correct lung compliance when using a self-inflating
Anne Marthe Boldingh1,2, Anne Lee Solevåg1, Jūratė Šaltytė Benth2,3
1Department of Paediatric and Adolescent Medicine, Akershus University Hospital, Akershus, Norway.
Aim:
Recognising changes in lung compliance can help clinicians to adjust initial inflations during resuscitation at birth. We examined whether physicians sensed low and normal compliance with a self-inflating bag before and after an educational intervention that used a manikin connected to a newborn lung simulator.
Methods:
We asked 43 physicians with neonatal duties to perform two low compliance ventilation attempts and two normal-compliance ventilation attempts in a randomised order at baseline and after the educational intervention, with 34 taking part in a retest three months later.
Results:
The physicians correctly recognised low and normal compliance in 71% and 66% of the ventilations at baseline, 80% and 66% of the ventilations after the intervention and 74% and 81% at retest. Correct recognition of normal compliance improved from baseline to retest (p = 0.04). Ventilations in low- vs normal-compliance settings resulted in lower tidal volumes (4.4 vs 23.0 mL, p < 0.001), lower ventilation rates (42 vs 51, p < 0.001) and higher peak inflating pressure (35.2 vs 31.4 cmH2 O, p < 0.001).
Conclusion:
Around one in four physicians failed to recognise correct compliance levels when using a self-inflating bag and showed limited improvement after an educational intervention. Ventilations in a low-compliance setting resulted in suboptimal ventilation.
More Related Videos
Related Concept Videos
Cardiopulmonary Resuscitation II: ACLS Airway Management
Assessment of Airway, Skin Color, and Use of Accessory Muscles
Introduction
The initial evaluation of a patient's respiratory system...
Respiratory System Abnormal Finding I: Inspection and Percussion
Inspection Findings
During an inspection, several findings may suggest the presence of respiratory distress or disease. Pursed-lip breathing, where exhalation is slowed by...
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Assessment of Respiration
Subjective Assessment: Nurses interview the patient to gather information directly during the subjective assessment. It includes questions about the individual's medical history, medications, and symptoms, focusing on past respiratory conditions like...
Physical Assessment of the Respiratory Tract II: Inspection
Chest Configuration
The chest configuration...