Electrochemiluminescence Resonance Energy Transfer System: Mechanism and Application in Ratiometric Aptasensor for
Yan-Mei Lei1, Wei-Xing Huang1, Min Zhao1
1The Key Laboratory of Eco-Environments in the Three Gorges Reservoir Region, College of Chemistry and Chemical Engineering, Southwest University, Chongqing 400715, China.
Abstract:
In this paper, a novel electrochemiluminescence resonance energy transfer (ECL-RET) system from O2/S2O8(2-) to a kind of amino-terminated perylene derivative (PTC-NH2) was demonstrated for the first time, which was then applied to construct a ratiometric aptasensor for lead ion (Pb(2+)) detection. First, gold-nanoparticles-functionalized fullerene nanocomposites (AuNPs@nano-C60) were coated on a glassy carbon electrode (GCE), and then thiol-modified assistant probes (APs) were attached on AuNPs@nano-C60/GCE. Then the resultant electrode was hybridized with capture probes (the aptamer of the Pb(2+), abbreviated as CPs) to generate DNA duplexes, which could induce PTC-NH2 to be intercalated into the dsDNA grooves by the electrostatic adsorption. Herein, ECL dual peaks at -0.7 V (vs Ag/AgCl) and -2.0 V (vs Ag/AgCl) were obtained when the prepared aptasensor was detected in air-saturated S2O8(2-) solution, which could be attributed to the emission of excited dimmers (π-excimers) ((1)(NH2-PTC)2*) and (1)(O2)2*, respectively. In the presence of Pb(2+), the dsDNA was unwound, and Pb(2+) G-quadruplex structure was generated because of the highly specific affinity between Pb(2+) and CPs, which made the PTC-NH2 release from the electrode surface. As a result, the ECL signal at -0.7 V was decreased, and the ECL signal around -2.0 V was increased. By measuring the ratio of ECL intensities at two excitation potentials, the developed aptasensor exhibited the linear response range from 1.0 × 10(-12) M to 1.0 × 10(-7) M with a detection limit of 3.5 × 10(-13) M (S/N = 3) for Pb(2+), which could offer an alternative analytical method with excellent properties of high selectivity, accuracy, and sensitivity.
Related Concept Videos
Photoluminescence: Applications
Enzyme-Linked Immunosorbent Assay
There are many different types of ELISAs, but they all involve an antibody molecule whose constant region binds an enzyme, leaving the variable region free to bind its specific antigen. Enzyme-substrate reaction allows the antigen to be visualized or...
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
Atomic Emission Spectroscopy: Overview
EDTA: Chemistry and Properties