Related Experiment Video
Updated: Apr 7, 2026

Electroretinogram Recording for Infants and Children under Anesthesia to Achieve Optimal Dark Adaptation and International Standards
Published on: September 3, 2020
A novel device for assessing dark adaptation in field settings
Alain B Labrique1, Amanda C Palmer2, Katherine Healy3
1Department of International Health, Johns Hopkins Bloomberg School of Public Health, Baltimore, MD, USA. alabriq1@jhu.edu.
A new Portable Field Dark Adaptometer (PFDA) offers a low-cost, easy way to measure dark adaptation and pupillary responses. This device shows a clear link between light intensity and pupil constriction, aiding in nutritional assessments.
Area of Science:
- Ophthalmology
- Public Health
- Biomedical Engineering
Background:
- Aberrant dark adaptation is linked to various diseases like vitamin A deficiency and hypoxia.
- Current methods for assessing scotopic vision are subjective, time-consuming, and difficult in resource-limited settings.
- There is a need for a compact, affordable, and user-friendly device for field-based dark adaptation assessment.
Purpose of the Study:
- To design and evaluate a Portable Field Dark Adaptometer (PFDA).
- To assess the device's ease of use and accuracy in depicting the light intensity-pupil response relationship.
- To provide a novel tool for nutritional assessment in diverse field conditions.
Main Methods:
- The PFDA uses a digital camera, flash, and Ganzfeld light source within goggles to record pupillary responses.
- Infrared camera captures pupillary changes to graded light stimuli after dark adaptation.
- Open-source software analyzed pupil size in videos; pupillary responsiveness was calculated as percent change.
Main Results:
- The PFDA was successfully deployed with minimal issues in multiple countries.
- A clear, linear relationship was observed between increasing light intensity and pupillary constriction.
- Light intensity strongly predicted pupillary response, irrespective of initial pupil size.
Conclusions:
- The PFDA demonstrates reliable measurement of dark adaptation through consistent physiological responses.
- Future work includes validating PFDA results against biochemical markers for vitamin A status and hypoxemia.
- The PFDA presents a promising new technology for nutritional assessment and has potential clinical applications.