Related Experiment Video
Updated: Apr 7, 2026

Preoxygenation Techniques for Tracheal Intubation in Critically Ill Adults Utilizing Oxygen Mask and Noninvasive Ventilation
Published on: December 5, 2025
A comparison of bilevel and ventilator-delivered non-invasive respiratory support
David Millar1, Brigitte Lemyre2, Haresh Kirpalani3
1Department of Neonatology, Royal Maternity Hospital, Belfast, UK.
Objective:
To compare the rates of death or bronchopulmonary dysplasia (BPD) in infants who received nasal intermittent positive pressure ventilation (NIPPV) delivered by a conventional mechanical ventilator (CMV) or a bilevel device.
Design:
A preplanned non-randomised comparison of infants randomised to the NIPPV arm of the NIPPV trial.
Setting:
Thirty-six tertiary neonatal units in three continents.
Patients:
Infants <1000 g and <30 weeks gestational age at birth.
Interventions:
Infants received treatment with CMV NIPPV or bilevel NIPPV, as a primary mode of respiratory support or following first extubation.
Results:
241 received mainly bilevel NIPPV and 215 mainly CMV NIPPV. No difference was found in death or BPD at 36 weeks corrected age (adjusted OR 0.88 (95% CI 0.57 to 1.35)). More deaths occurred in infants receiving bilevel NIPPV (9.4%) than in CMV NIPPV (2.3%) (adjusted OR 5.01: 95% CI 1.74 to 14.4). There was a corresponding but not statistically significant decrease in BPD in the bilevel NIPPV group (30% vs 37%) (adjusted OR 0.64 (95% CI 0.41 to 1.02)). No difference was observed in extubation failure or age at last extubation. A post hoc test of interaction between device type and synchronisation was not statistically significant.
Conclusions:
We did not observe a statistically significant difference in the composite outcome of death or BPD between infants who received mostly bilevel NIPPV compared with mostly CMV NIPPV. Differences in component outcomes of morbidity and BPD may be due to the competing nature of these outcomes or differences in baseline characteristics of infants.
Trial Registration Number:
NCT00433212.
Related Concept Videos
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Mechanical Ventilation I: Indication and Settings
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Cardiopulmonary Resuscitation II: ACLS Airway Management