Characterization of Recombination Effects in a Liquid Ionization Chamber Used for the Dosimetry of a Radiosurgical Accelerator
Published on: May 9, 2014
Determination of the ion recombination correction factor for intraoperative electron beams
Majid Ghorbanpour Besheli1, Ioannis Simiantonakis1, Klemens Zink2
1Department of Radiotherapy and Radiation Oncology, University Hospital of Duesseldorf, Germany; Faculty of Physics/Medical Physics, Heinrich-Heine University of Duesseldorf, Germany.
Abstract:
The ion recombination correction factor (ks) is determined for the Advanced Markus chamber exposed to electron beams produced by a dedicated intraoperative radiation therapy (IORT) accelerator at medium dose-per-pulse values. The authors evaluate five different methods. Three of them are known as Boag's modified expressions, which are based on the two-voltage-analysis method and include the free-electron component. In the fourth method the IAEA TRS-398 protocol is applied, which uses the same two-voltage-analysis method but ignores the free-electron component, and finally the fifth approach is known as the Jaffé plot. ks values were obtained in the range of 4 mGy/pulse to 42 mGy/pulse and were compared with ks values determined by means of radiochromic films, which are independent of the dose rate. It was found that ks values that resulted from the three Boag's modified expressions and the TRS-398 protocol deviated by on average 1.5% and 1.4%, respectively, from the reference ks values based on film dosimetry. These results are within the estimated relative uncertainty of ±3%. On the other hand, the absolute deviation of each method depends on the dose-per-pulse value at which the method is investigated. In conclusion, in the medium dose-per-pulse range all Boag's modified expressions could be used for ks determination. Above a dose-per-pulse value of 35 mGy/pulse, the TRS-398 approach should be avoided. At 27 mGy/pulse and a maximum operation voltage of 300 V the ks value resulting from the Jaffé plot showed a 0.3% deviation from the reference value. More investigation on the Jaffé plot is necessary at higher dose-per-pulse values.
More Related Videos
Related Concept Videos
Conservative Site-specific Recombination and Phase Variation
The recognition sites for Cre recombinase called LoxP...
Long-patch Base Excision Repair
Homologous Recombination
Gene Conversion
Carrier Generation and Recombination
This process is given by the generation rate G and is efficient due to the conservation of momentum between the valence band maximum and conduction band minimum.
Indirect generation involves an...
Nucleotide Excision Repair