Limitation of motion and shoulder disabilities in patients with cardiac implantable electronic devices
Gulin Findikoglu1, Bekir S Yildiz, Musa Sanlialp
1Departments of aPhysical Medicine and Rehabilitation bCardiology cBiostatistics, Faculty of Medicine, University of Pamukkale, Denizli, Turkey.
Insights
Patients with cardiac implantable electronic devices (CIEDs) often experience shoulder range of motion (ROM) limitations, particularly in the short-term post-implantation. This may lead to shoulder disability, impacting upper extremity function.
Area of Science:
- Orthopedics
- Cardiology
- Rehabilitation Medicine
Background:
- Cardiac implantable electronic devices (CIEDs) are common treatments for cardiac arrhythmias.
- Potential side effects include upper extremity functional limitations and shoulder range of motion (ROM) deficits.
- The impact of implantation time on these deficits requires further investigation.
Purpose of the Study:
- To investigate shoulder ROM and upper extremity function in patients with CIEDs.
- To compare short-term recipients (STRs) with long-term recipients (LTRs).
- To identify factors contributing to shoulder dysfunction post-CIED implantation.
Main Methods:
- Shoulder ROM was measured using a digital goniometer, comparing the CIED side to the contralateral arm.
- Functional status was assessed using the Constant-Murler Score, Shoulder Pain Disability Index (SPDI), and Shoulder Disability Questionnaire (SDQ).
- Patients were categorized into STRs (<3 months post-implantation) and LTRs (>3 months post-implantation).
Main Results:
- Significant limitations in shoulder flexion, abduction, and internal rotation were observed on the CIED side compared to the control arm.
- STRs exhibited significant differences in shoulder flexion, abduction, and external rotation compared to LTRs.
- Shoulder disability, measured by SPDI and SDQ, was more prominent in STRs, although Constant-Murler Scores did not differ significantly between groups.
Conclusions:
- Patients with CIEDs experience shoulder ROM limitations and functional disability, more pronounced in the short term.
- Potential contributing factors include pain, CIED-pectoral muscle association, capsular pathology, and patient avoidance behaviors.
- Early assessment and management of shoulder function may be crucial for CIED recipients.
Abstract:
The aim of this study is to investigate the presence of limitations in the shoulder range of motion (ROM) or the loss of upper extremity function on the affected side in patients with cardiac implantable electronic devices (CIEDs) with respect to the implantation time. Forty-nine patients (30 men and 19 women), mean age 64.84±11.18 years, who had been living with a CIED for less than 3 months were included in the short-term recipient (STR) group and 127 patients (85 men and 42 women), mean age 64.91±14.70 years, and with the device for longer than 3 months were included in the long-term recipients group. Shoulder ROMs were measured using a digital goniometer. The other arm was used as the control. The Constant-Murler Score, Shoulder Pain Disability Index, and Shoulder Disability Questionnaire were used to assess the functional status. Limitations of ROM for flexion, abduction, and internal rotation were found to be significantly lower in the arm on the side of CIED compared with the control arm. Significant differences in shoulder flexion, abduction, and external rotation in STRs were found compared with long-term recipient (P<0.05). However, the functional comparison of groups by the Constant-Murler Score was not significant. A low to moderate amount of shoulder disability measured by Shoulder Pain Disability Index and Shoulder Disability Questionnaire was found in patients with CIEDs, which was more prominent in STRs (P<0.05). Pain, association of CIED with pectoral muscles, a possible subtle ongoing capsular pathology, and avoidance behaviors of patients to minimize the risk of lead dislodgement might be related to restriction of motion and function in the shoulder joint in patients with CIEDs.
More Related Videos
16:40A New Single Chamber Implantable Defibrillator with Atrial Sensing: A Practical Demonstration of Sensing and Ease of Implantation
Published on: February 28, 2012
06:29Wireless Telemetry Device Implantation in a Fontan Ovine Model for Continuous and Long-Term Hemodynamic Monitoring
Published on: May 2, 2025
Related Concept Videos
Cardiomyopathy III: Hypertrophic Cardiomyopathy
Cardiomyopathy V: Interprofessional Care
Cardiomyopathy II: Dilated Cardiomyopathy
Imbalances in Cardiac Output
CHF can occur due to the failure of either side of the heart. Left-side failure leads to pulmonary congestion—the right side continues to send...
Mechanism of Cardiac Arrhythmias
Cardiac Catheterization IV: Nursing Management