Related Experiment Video
Updated: Apr 7, 2026

Automated 90Sr Separation and Preconcentration in a Lab-on-Valve System at Ppq Level
Published on: June 6, 2018
Emergency Radiobioassay Method for Determination of ⁹⁰Sr and ²²⁶Ra in a Spot Urine Sample
Baki B Sadi1, Allison Fontaine2, Daniel McAlister3
1†Radiation Protection Bureau, Health Canada, 775 Brookfield Road, A.L. 6302D, Ottawa, ON K1A 1C1, Canada.
Abstract:
A new radiobioassay method has been developed for simultaneous determination of (90)Sr and (226)Ra in a spot urine sample. The method is based on a matrix removal procedure to purify the target radionuclides from a urine sample followed by an automated high performance ion chromatographic (HPIC) separation of (90)Sr and (226)Ra and offline radiometric detection by liquid scintillation counting (LSC). A Sr-resin extraction chromatographic cartridge was used for matrix removal and purification of (90)Sr and (226)Ra from a urine sample prior to its introduction to the HPIC system. The HPIC separation was carried out through cation exchange chromatography using methanesulfonic acid (75 mM) as the mobile phase at 0.25 mL/min flow rate. The performance criteria of the method was evaluated against the American National Standard Institute ANSI/HPS N13.30-2011 standard for the root mean squared error (RMSE) of relative bias (Br) and relative precision (SB) at two different spiked activity levels. The RMSE of Br and SB for (90)Sr and (226)Ra were found to be satisfactory (≤0.25). The minimum detectable activity (MDA) of the method for (90)Sr and (226)Ra are 2 Bq/L and 0.2 Bq/L, respectively. The MDA values are at least 1/10th of the concentrations of (90)Sr (190 Bq/L) and (226)Ra (2 Bq/L) excreted in urine on the third day following an acute exposure (inhalation) that would lead to an effective dose of 0.1 Sv in the first year. The sample turnaround time is less than 8 h for simultaneous determination of (90)Sr and (226)Ra.
More Related Videos
07:52A Novel Technique for Raman Analysis of Highly Radioactive Samples Using Any Standard Micro-Raman Spectrometer
Published on: April 12, 2017
12:04Fluorescence-Activated Cell Sorting-Radioligand Treated Tissue FACS-RTT to Determine the Cellular Origin of Radioactive Signal
Published on: September 10, 2021
Related Concept Videos
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Radioactive Decay and Radiometric Dating
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Microbial Bioremediation of Uranium