Objectives:
Blood insulin and C-peptide are key investigations in the differential diagnosis of hypoglycaemia. Analogues of insulin have modified primary-sequences compared to native human insulin, as such may not cross react with insulin assays. This has important implications in detecting surreptitious or malicious insulin administration. The aim of this study is to assess the cross-reactivity of all insulins currently listed in the British National Formulary (BNF65, 2013) in clinical insulin assays currently used in UK clinical laboratories.
Design And Methods:
Sample sets were prepared for all 15 exogenous insulin classes listed in the BNF, at concentrations of 1000 pmol/L and 300 pmol/L, using pooled human serum. Samples were sent blinded to 5 participating analytical laboratories to cover analysis on the 10 major clinical insulin assays used in the UK.
Results:
The ability of insulin assays to detect exogenous insulin preparations was highly variable and ranged from 0% to >140% for a single exogenous insulin. Four assays were highly specific for the human insulin sequence and had no cross-reactivity with any synthetic analogue insulin. Two detected all insulin types (human sequence, animal and synthetic analogue), with the remaining having variable cross-reactivity.
Conclusion:
The cross-reactivity of the 15 exogenous insulin preparations is highly variable in the assays used in clinical laboratories around the UK. It is important that laboratories and clinicians are aware of the limitations of their local assays to avoid missing the important diagnosis of hypoglycaemia secondary to excessive exogenous insulin. Where necessary, samples should be referred to specialist centres for insulin analysis and ideally by a validated and fully-quantitative mass spectrometry-based method.
Related Concept Videos
Insulin Formulations: Types and Delivery
Short-acting insulins are divided into...
Insulin: Dosing Regimen and Adverse Effects
The basal dose constitutes about 40%-50% of the total daily dose, with the rest as premeal insulin. The mealtime insulin dose should mirror...
Insulin: Biosynthesis, Chemistry, and Preparation
Damage or functional impairment of β-cells inhibits insulin production, leading to diabetes. Diabetes treatment...
Hypoglycemia and Glucagon
Diabetes Mellitus: Overview and Type I Subtype
Type 1 diabetes is an autoimmune disease in which the immune system mistakenly attacks and destroys the insulin-producing beta cells in the pancreas. As a result, the body is unable to produce sufficient insulin, and individuals with...
Glucagon-like Receptor Agonists
GLP-1, when administered in high doses intravenously, triggers insulin secretion, inhibits glucagon release, slows gastric emptying, reduces food intake, and restores normal insulin secretion. However, its rapid inactivation by...