A Novel Non-invasive Method for the Detection of Elevated Intra-compartmental Pressures of the Leg
Published on: May 31, 2019
Automatic Measurement of Venous Pressure Using B-Mode Ultrasound
Abstract:
Central venous pressure (CVP) information is crucial in clinical situations, such as cardiac failure, intravascular volume overload, and sepsis. The measurement of CVP, however, requires the catheterization of vena cava through the subclavian or internal jugular veins, which is an impractical and costly procedure with related risk of complications. Peripheral venous pressure (PVP), which correlates with CVP under certain patient positioning, can be measured noninvasively using ultrasound via controlled compressions of a superficial vein. This paper presents an automatic system for acquiring such noninvasive measurements. Robust signal and image processing techniques developed for this purpose are introduced in this paper. The proposed standalone mobile platform collects images in real time from the display output of any ultrasound machine, meanwhile measuring the pressure on the skin underneath the ultrasound transducer via a liquid-filled pouch. The image and pressure data are synchronized through an automated temporal calibration procedure. During forearm compressions, blood vessels are detected and tracked in the images using robust geometric (ellipse) models, the parameters of which are used further in the model-based estimation of PVP. The proposed system was tested in 56 image sequences on 14 healthy volunteers, and was shown to achieve measurements with errors comparable to or lower than the interoperator variability of expert manual assessments.
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Measurement of Blood Pressure
Assessing Blood pressure in the Leg
Preparation:
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure: