Related Experiment Video
Updated: Apr 6, 2026

In Vitro Application of a Wireless Sensor in Flexion-Extension Gap Balance of Unicompartmental Knee Arthroplasty
Published on: May 5, 2023
Functional Outcomes of a New Mobile-Bearing Ultra-Congruent TKA System: Comparison With the Posterior Stabilized
Morey Vivek Machhindra1, Jong Yeal Kang1, Yeon Gwi Kang1
1Department of Orthopaedic Surgery, Seoul National University Bundang Hospital, Seongnam, South Korea.
Abstract:
We determined whether a new mobile-bearing ultra-congruent (UC) TKA system provides better functional outcomes than an established posterior-stabilized (PS) prosthesis. The functional outcomes (motion arc, AKS scores, WOMAC Index, and SForm-36 scores evaluated at 1 and 2 years postoperatively), satisfaction and incidences of adverse events were compared between the knees implanted with mobile-bearing UC prosthesis (n=103) and the mobile-bearing PS prosthesis (n=99). At 2 years, mobile-bearing UC TKAs showed similar functional outcomes and satisfaction, but smaller motion arc compared to mobile-bearing PS TKAs (126° vs. 131°). There were no differences in the incidence of adverse events. Mobile-bearing UC prosthesis can be considered a safe and viable alternative to the PS design, with an expectation of smaller postoperative maximum flexion.
More Related Videos
09:01Treatment of Ankle Osteoarthritis with Total Ankle Replacement Through a Lateral Transfibular Approach
Published on: January 24, 2018
09:51The Transition to an Anterior-Based Muscle Sparing Approach Improves Early Postoperative Function but is Associated with a Learning Curve
Published on: September 7, 2022