Chromatographic Fingerprinting by Template Matching for Data Collected by Comprehensive Two-Dimensional Gas Chromatography
Published on: September 2, 2020
Comparison of the most recent chromatographic approaches applied for fast and high resolution separations: Theory and
Szabolcs Fekete1, Jean-Luc Veuthey1, Davy Guillarme1
1School of Pharmaceutical Sciences, University of Geneva, University of Lausanne, Boulevard d'Yvoy 20, 1211 Geneva 4, Switzerland.
Abstract:
In the last few years, there have been a lot of advances in the field of liquid chromatography (LC) and supercritical fluid chromatography (SFC). The intent of this review is to summarize the available approaches including the use of high mobile phase temperature, extended system upper pressure limit, fully porous particles down to sub-2μm, superficially porous particles (SPP) from 1.3 to 5μm, as well as first and second generations silica-based monoliths. Increasing the mobile phase temperature in LC is one of the most attractive strategies to decrease analysis time, while it is not always the best way to achieve very high plate count. Silica-based monoliths available since 2000, may be more competitive if the upper pressure limit of the column can be extended to 400-600bar (modification of the PEEK cladding). Extending the system pressure in UHPLC beyond 1000bar is a powerful strategy to increase the maximal achievable efficiency in LC, but its impact on throughput remains limited and frictional heating effects should be considered with care. Modern columns packed with SPP introduced in 2007 are attractive in both LC and SFC. Stationary phases packed with 5 and 1.3μm SPP are currently the most promising strategies for high resolution and high throughput separations in LC, respectively. In SFC, columns packed with 2.7μm SPP particles represent a good compromise between throughput and resolution. Finally, to attain the highest possible kinetic performance in SFC, there is a need to further reduce extra-column band broadening (system dispersion, σext(2)) down to 10μL(2) or less. In addition, the system upper pressure limit should be extended to ∼800bar, to have a sufficient flexibility, particularly when working with a mobile phases containing a relatively high amount of organic solvent (e.g. 20-40% MeOH).
More Related Videos
10:17High-throughput and Comprehensive Drug Surveillance Using Multisegment Injection-Capillary Electrophoresis-Mass Spectrometry
Published on: April 23, 2019
10:21Automated Hydrophobic Interaction Chromatography Column Selection for Use in Protein Purification
Published on: September 21, 2011
Related Concept Videos
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...
Chromatographic Methods: Terminology
Principles Of Column Chromatography
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
Ion-Exchange Chromatography
Chromatography: Introduction
The phase in which the compounds linger or on which the compounds adsorb is called the stationary phase, whereas the mobile phase is the solvent that carries the solutes to be analyzed. In traditional column chromatography, the mixture flows through the stationary phase, and the compounds partition between the stationary and mobile phases...