Related Experiment Video
Updated: Apr 6, 2026

Multi-Scale Modification of Metallic Implants With Pore Gradients, Polyelectrolytes and Their Indirect Monitoring In vivo
Published on: July 1, 2013
Impact of implant composition of twin-screw extruded lipid implants on the release behavior
Marie-Paule Even1, Sharan Bobbala2, Kok Liang Kooi2
1Department of Pharmacy, Pharmaceutical Technology and Biopharmaceutics, Ludwig-Maximilians-Universität München, Butenandtstr. 5, D-81377 Munich, Germany.
The development of vaccine delivery systems that will remove or reduce the need for repeated dosing has led to the investigation of sustained release systems. In this context, the duration of antigen release is of great importance as is the requirement for concomitant adjuvant release. In this work, lipid implants consisting of cholesterol (CHOL), soybean lecithin, Dynasan 114 (D114), the model antigen ovalbumin (OVA) and the adjuvant Quil-A (QA) were produced by twin-screw extrusion. The release of antigen and adjuvant was investigated in vitro and we observed complete OVA release over a period of 7 days while QA was released in a linear fashion over a period of up to 12 days. In order to extend OVA release, lipid implants were subjected to post-extrusion curing at 45-55°C. The OVA release could be extended to up to 14 days. Furthermore the influence of the implant composition on the release of the model antigen was investigated. It was shown that the percentage of cholesterol in particular plays an important role in modulating release.
The development of vaccine delivery systems that will remove or reduce the need for repeated dosing has led to the investigation of sustained release systems. In this context, the duration of antigen release is of great importance as is the requirement for concomitant adjuvant release. In this work, lipid implants consisting of cholesterol (CHOL), soybean lecithin, Dynasan 114 (D114), the model antigen ovalbumin (OVA) and the adjuvant Quil-A (QA) were produced by twin-screw extrusion. The release of antigen and adjuvant was investigated in vitro and we observed complete OVA release over a period of 7 days while QA was released in a linear fashion over a period of up to 12 days. In order to extend OVA release, lipid implants were subjected to post-extrusion curing at 45-55°C. The OVA release could be extended to up to 14 days. Furthermore the influence of the implant composition on the release of the model antigen was investigated. It was shown that the percentage of cholesterol in particular plays an important role in modulating release.
Related Concept Videos
Modified-Release Drug Delivery Systems: Rate-Programmed II
Factors Influencing Drug Absorption: Pharmaceutical Parameters
Modified-Release Drug Delivery Systems: Influencing Factors
Modified-Release Drug Delivery Systems: Drug Release Characteristics