Impact of Dose-Modified Protocols on Radiation Doses in Patients Undergoing CT Examinations following Image-Guided
Yasir Andrabi1, Thomas S Saadeh1, Raul N Uppot1
1Department of Radiology, Division of Abdominal Imaging and Intervention, Massachusetts General Hospital, Harvard Medical School, 55 Fruit St., White 270, Boston, MA 02114.
Purpose:
To investigate the impact of dose-modified (DM) scan protocols on decreasing radiation exposure from computed tomography (CT) scans obtained following image-guided catheter procedures.
Materials And Methods:
In this retrospective analysis, between December 2012 and June 2014, 192 patients (mean age, 60.7 y; 102 men) who underwent abdomen/pelvis CT examinations for catheter placement follow-up were included. The standard-dose (SD) baseline CT parameters included tube potential of 120 kVp, tube current of 75-550 mA, and noise index (NI) of 18-22. Weight-based scan parameters applied for follow-up CT were based on two reconstruction algorithms: filtered back projection (FBP; 120 kVp, 75-350 mA, NI = 30) and iterative reconstruction technique (IRT; 100/120 kVp, 75-250/350 mA, NI = 35). Two readers reviewed image quality (IQ) of follow-up and baseline CT examinations for 22 randomly sampled patients. Radiation doses were retrieved by dose monitoring software.
Results:
Compared with baseline, DM follow-up CT protocols enabled substantial (62.4%) dose reductions (mean CT dose indexes: 4.1 mGy at follow-up, 10.9 mGy at baseline; P < .0001). Doses were significantly lower for IRT follow-up CT examinations compared with FBP (mean CT dose indexes: IRT, 3.6 mGy; FBP, 4.6 mGy; P < .05). In 47 patients with more than one follow-up CT examination (mean, 3.1 examinations per patient; range, 2-6), the observed cumulative radiation dose (CRD) was 42.1% lower than the expected CRD (observed, 1,437.9 mGy·cm; expected, 2,483.6 mGy·cm; P < .0001). Subjective IQ scores were acceptable for follow-up CT examinations (follow-up, 3.6; baseline, 4; P < .05).
Conclusions:
DM CT examinations enable substantial dose reduction (62.4%) for each follow-up examination compared with SD baseline scans, without any IQ concerns. Use of IRT decreases dose by an additional 22%. The CRD is lowered by 42% in patients undergoing multiple DM follow-up CT examinations.
Related Concept Videos
Imaging Studies for Cardiovascular System V: CT
Radiological Investigation I: X-ray and CT
Imaging Studies III: Computed Tomography
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Cardiac Catheterization I: Pre-Procedure Overview
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...