Related Experiment Video
Updated: Apr 6, 2026

Tracking the Mammary Architectural Features and Detecting Breast Cancer with Magnetic Resonance Diffusion Tensor Imaging
Published on: December 15, 2014
Evaluation of the orbit using contrast-enhanced radial 3D fat-suppressed T1 weighted gradient echo (Radial-VIBE)
Lev Bangiyev1, Eytan Raz2, Tobias K Block2
11 Department of Radiology, Stony Brook University Medical Center, Stony Brook, NY, USA.
Objective:
Contrast-enhanced fat-suppressed T1 weighted (T1W) two-dimensional (2D) turbo spin echo (TSE) and magnetization-prepared gradient echo (MPRAGE) sequences with water excitation are routinely obtained to evaluate orbit pathology. However, these sequences can be marred by artefacts. The radial-volume-interpolated breath-hold examination (VIBE) sequence is a motion-robust fat-suppressed T1W sequence which has demonstrated value in paediatric and body imaging. The purpose of our study was to evaluate its role in assessing the orbit and to compare it with routinely acquired sequences.
Methods:
A Health Insurance Portability and Accountability Act-compliant and institutional review board-approved retrospective study was performed in 46 patients (age range: 1-81 years) who underwent orbit studies on a 1.5-T MRI system using contrast-enhanced Radial-VIBE, MPRAGE and 2D TSE sequences. Two radiologists blinded to the sequence analysed evaluated multiple parameters of image quality including motion artefact, degree of fat suppression, clarity of choroidal enhancement, intraorbital vessels, extraocular muscles, optic nerves, brain parenchyma and evaluation of pathology. Each parameter was assessed on a 5-point scale, with a higher score indicating the more optimal examination. Mix model analysis of variance and interobserver variability were assessed.
Results:
Radial-VIBE demonstrated superior quality (p < 0.001) for all orbit parameters when compared with MPRAGE and 2D TSE. Interobserver agreement demonstrated average fair-to-good agreement for degree of motion artefact (0.745), fat suppression (0.678), clarity of choroidal enhancement (0.688), vessels (0.655), extraocular muscles (0.675), optic nerves (0.518), brain parenchyma (0.710) and evaluation of pathology (0.590).
Conclusion:
Radial-VIBE sequence demonstrates superior image quality when evaluating the orbits as compared with conventional MPRAGE and 2D TSE sequences.
Advances In Knowledge:
Radial-VIBE employs unique non-Cartesian k-space sampling in a radial or spoke-wheel fashion which provides superior image quality improving diagnostic capability in the evaluation of the orbits.
More Related Videos
Related Concept Videos
Imaging Studies for Cardiovascular System IV: CMRI
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
Magnetic Resonance Imaging
Imaging Studies IV: Magnetic Resonance Imaging
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation

