Background:
The pharmacokinetics for sevoflurane and desflurane makes them suitable for low-flow anesthesia. The aim of the present study was to assess the use of desflurane and sevoflurane at constant vaporizer settings and fixed low fresh gas flows.
Methods:
One hundred ASA 1-2 patients undergoing elective laparoscopic surgery were randomized into 4 groups (25 patients each): a fixed fresh gas flow 1.0 or 0.5 L/min with desflurane (D1.0 and D0.5) or sevoflurane (S1.0 and S0.5) throughout anesthesia. A fixed vaporizer setting, sevoflurane 6% and desflurane 18% was used during wash-in. Time to reach 1 and 1.5 minimum alveolar concentration (MAC), emergence and gas consumption from start to end of surgery was studied.
Results:
Time to reach 1 MAC age adjusted desflurane or sevoflurane was D0.5 8.5±1.7, D1.0 3.7±0.7, S0.5 15.2±2.4 and S1.0 6.2±1.3 minutes, respectively (P<0.001), and times to increase from 1 to 1.5 MAC differed also significantly. Desflurane anesthesia was associated to significantly shorter time to extubation 6.7±2.3 vs. 10±2.3 minutes for sevoflurane (P<0.001). The amount of agent consumed g/min. was significantly reduced for both 0.5 L/min groups: 30% less for desflurane and 19% for sevoflurane.
Conclusions:
We found an almost twice as rapid wash-in with desflurane and expectedly faster emergence. Gas consumption was lower at 0.5 L/min than it was at 1 L/min for both gases studied however most pronounced for desflurane. Desflurane has clear advantages for minimal fresh gas flow anesthesia.
More Related Videos
09:36Halogenated Agent Delivery in Porcine Model of Acute Respiratory Distress Syndrome via an Intensive Care Unit Type Device
Published on: September 24, 2020
03:02Application of Dixon's Up-and-Down Design to Estimate the Minimum Alveolar Concentration of Sevoflurane in Rats with Refined Movement Classification
Published on: July 25, 2025
Related Concept Videos
Inhalational Anesthetics: Overview
Stages of General Anesthesia
Parenteral Anesthetics: Overview
General Anesthesia: Overview
General anesthesia induces unconsciousness in the whole body, while the others target specific areas or sensations. It is administered to minimize adverse effects, maintain...
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...
Mechanical Ventilation I: Indication and Settings