Coefficient of Friction of Human Corneal Tissue
Tawnya Wilson1, Rudolf Aeschlimann, Samuele Tosatti
1*Johnson & Johnson Vision Care, Inc, Jacksonville, FL; and †SuSoS AG, Dübendorf, Switzerland.
Purpose:
A novel property evaluation methodology was used to determine the elusive value for the human corneal coefficient of friction (CoF).
Methods:
Using a microtribometer on 28 fresh human donor corneas with intact epithelia, the CoF was determined in 4 test solutions (≥5 corneas/solution): tear-mimicking solution (TMS) in borate-buffered saline (TMS-PS), TMS in phosphate-buffered saline (TMS-PBS), TMS with HEPES-buffered saline (TMS-HEPES), and tear-like fluid in PBS (TLF-PBS).
Results:
Mean (SD) CoF values ranged from 0.006 to 0.015 and were 0.013 (0.010) in TMS-PS, 0.006 (0.003) in TMS-PBS, 0.014 (0.005) in TMS-HEPES, and 0.015 (0.009) in TLF-PBS. Statistically significant differences were shown for TMS-PBS versus TLF (P = 0.0424) and TMS-PBS versus TMS-HEPES (P = 0.0179), but not for TMS-PBS versus TMS-PS (P = 0.2389).
Conclusions:
Successful measurement of the fresh human corneal tissue CoF was demonstrated, with values differing in the evaluated buffer solutions, within this limited sample size.