BioWatch: A Noninvasive Wrist-Based Blood Pressure Monitor That Incorporates Training Techniques for Posture and Subject Variability
Related Experiment Video
Updated: Apr 6, 2026

Tilt Testing with Combined Lower Body Negative Pressure: a "Gold Standard" for Measuring Orthostatic Tolerance
Published on: March 21, 2013
Abstract:
Noninvasive continuous blood pressure (BP) monitoring is not yet practically available for daily use. Challenges include making the system easily wearable, reducing noise level and improving accuracy. Variations in each person's physical characteristics, as well as the possibility of different postures, increase the complexity of continuous BP monitoring, especially outside the hospital. This study attempts to provide an easily wearable solution and proposes training to specific posture and individual for further improving accuracy. The wrist watch-based system we developed can measure electrocardiogram and photoplethysmogram. From these two signals, we measure pulse transit time through which we can obtain systolic and diastolic blood pressure through regression techniques. In this study, we investigate various functions to perform the training to obtain blood pressure. We validate measurements on different postures and subjects, and show the value of training the device to each posture and each subject. We observed that the average RMSE between the measured actual systolic BP and calculated systolic BP is between 7.83 to 9.37 mmHg across 11 subjects. The corresponding range of error for diastolic BP is 5.77 to 6.90 mmHg. The system can also automatically detect the arm position of the user using an accelerometer with an average accuracy of 98%, to make sure that the sensor is kept at the proper height. This system, called BioWatch, can potentially be a unified solution for heart rate, SPO2 and continuous BP monitoring.
Related Concept Videos
Pre-Procedural Guidelines for Assessing Blood Pressure
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Errors occurring during blood pressure monitoring
Several factors...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Assessment of blood pressure in brachial artery(two-step method)