Purpose:
To compare clinical outcomes after implantation of TECNIS diffractive multifocal intraocular lenses (IOLs) with different add powers.
Design:
Prospective, comparative, interventional case series.
Methods:
Subjects underwent cataract extraction and diffractive multifocal IOL implant. Subjects had an additional add power of +2.75 diopters (D) (Group 1, 23 eyes), +3.25 D (Group 2, 21 eyes), or +4.00 D (Group 3, 21 eyes). Evaluations were performed 1 and 3 months following cataract surgery, including measurement of monocular uncorrected distance visual acuity (UDVA), refractive error (manifest refraction [MR]), and monocular uncorrected near visual acuity (UNVA) at 33, 40, and 50 cm. At 3 months, internal aberrations and contrast sensitivity were evaluated and subjects completed a questionnaire on outcomes satisfaction, visual symptoms, and spectacle use.
Results:
Sixty-five eyes (43 subjects) were included. After surgery, no significant differences between groups were observed in UDVA and MR values. UNVA at 33 cm was best in Group 3 (1 month: P = .032; 3 months: P = .031). Three months after surgery, UNVA was best in Group 1 at 50 cm (P = .017). No significant differences in internal aberration and contrast sensitivity were observed between groups and surgical satisfaction was worst in Group 3 (P = .001). A total of 87.0%, 85.7%, and 76.9% had spectacle independence in Groups 1, 2, and 3, respectively (P = .080).
Conclusions:
TECNIS diffractive multifocal IOLs with lower add powers provide good vision over longer working distances and excellent distant vision. Subjects with lower add power had greater satisfaction, more spectacle independence, and fewer visual symptoms than those with +4.00 D add.
More Related Videos
05:14Comparison of Agreement and Accuracy using Binocular Wavefront Optometer with Autorefractor and Phoropter
Published on: September 16, 2025
04:59Author Spotlight: Enhancing Visual Outcomes in Cataract Surgery: A Novel Technique to Prevent Posterior Capsular Opacification Through IOL Rotation
Published on: July 7, 2023
Related Concept Videos
Focusing of Light in the Eye
Angle Closure Glaucoma: Treatment
Open Angle Glaucoma: Treatment
Drugs such as carbonic anhydrase inhibitors, α2- and...