A Methodological Approach to Non-invasive Assessments of Vascular Function and Morphology
Published on: February 7, 2015
Validation of a new method for non-invasive assessment of vasomotor function
Elizabeth A Ellins1, Karl J New2, Dev B N Datta3
1Institute of Molecular and Experimental Medicine, Cardiff University, UK Institute of Life Sciences, Swansea University, UK.
Background:
Reactive hyperaemia induces a slowing of pulse wave velocity (PWV) in conduit arteries of healthy subjects (flow-mediated slowing (FMS)). This could be an alternative method for assessing peripheral vasomotor function to the gold standard method of flow-mediated dilatation (FMD) a more expensive and technically demanding technique. We aimed to assess the reproducibility of FMS in healthy participants and to test its ability to detect differences in vasomotor function in patients with familial hypercholesterolaemia (FH) and post-lipoprotein apheresis (LA) treatment.
Methods:
Altogether 25 healthy participants were studied on two occasions to assess reproducibility of FMS. In a case control study of 22 patients with FH and matched healthy controls, FMD and FMS were compared. An intervention study in 12 patients with FH looked at the impact of a single LA treatment on FMS assessed pre and post treatment.
Results:
FMS demonstrated good reproducibility (coefficient of variation (CoV) 7.3%). Patients with FH had reduced FMS in comparison to matched healthy controls (FMS% FH -15.13 ± 5.04% vs controls -18.41 ± 5.15%, p = 0.023), with no difference in FMD% between the two groups. A single LA treatment significantly improved FMS (pre -18.81 ± 9.84 vs post -24.09 ± 7.61%, p = 0.016).
Conclusions:
FMS is a reproducible technique, which is able to detect differences in vasomotor function both in a condition associated with endothelial dysfunction and following an acute intervention known to improve endothelial function. This simple technique has potential for accessible assessment of vasomotor function in clinical studies.
Related Concept Videos
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Assessment of blood pressure in brachial artery(two-step method)
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment: